2866598 Phoenix Contact, 2866598 Datasheet - Page 12

UPS 4A 12VDC

2866598

Manufacturer Part Number
2866598
Description
UPS 4A 12VDC
Manufacturer
Phoenix Contact
Series
Minir
Datasheets

Specifications of 2866598

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
48W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
12 VDC @ 4A
Size / Dimension
4.53" L x 2.66" W x 3.90" H (115mm x 67.5mm x 99mm)
Operating Temperature
-25°C ~ 70°C
Power (watts) - Rated
48W
Efficiency
82%
Approvals
cUL, EN, UL, VDE
Output Voltage Rating
12 V
Number Of Outlets
1
Tower / Rackmount
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
104211_en_00
15
16
O U
0 ,5 1
3 0
t
2 0
T D
m a
x
[
m in
1 5
C
2
1 2
]
1 0
3
5
V 4
A
60
10
1 0
V D
I N
30
10
-1 6
C
A C
L (
1
+ )
1
1 0
0 -
N (
0
R 1
R e
P o
2 4
B a
- )
B a
w e
m o
t. -C
O v
0 V
Rechargeable battery module
Remote shutdown ("Remote")
O F
t. -M
r in
R 2
O N
A la
e rl
h a
t e
F
o d
rg e
O K
o a
rm
e
d
1
2
B a
t t e
r y
= 1,6Ah
= 2,6Ah
0,5
1
1
1,5
2
2
2,5
3
Current [A]
3,5
4
The rechargeable battery module is connected to the power
supply unit through the "Battery +" and the "Battery –" terminal
blocks. The fuse of the rechargeable battery module must be
removed when installing or replacing the module.
We recommend to use the following battery modules:
1. MINI-BAT 12DC/1.6Ah (Order No. 2866572)
2. MINI-BAT 12DC/2.6Ah (Order No. 2866569)
The buffer mode might be terminated after the preset time or
due to an external shutdown. If the device is to be switched off
after a certain period, the time for it is set using the selector
switch at the front of the device. The device can be switched
on in the buffer mode again after reconnecting the power
supply.
The device has a remote shutdown with a UPS function for
deliberate shutdown. Remote shutdown must be deactivated
for the device to switch over to the buffer mode in the event of
a supply voltage failure.
Remote shutdown inactive
The "Remote shutdown R1" and "Remote shutdown R2"
terminal points are short-circuited (e.g., with a plug-in bridge)
OR 12 V DC is present at the "Remote shutdown R2" terminal
point.
Remote shutdown active
The "Remote shutdown R1" and "Remote shutdown R2"
terminal points are not short-circuited (e.g., with a plug-in
bridge) OR 0 V is present at the "Remote shutdown R2"
terminal point.
The power supply unit switches over to the buffer mode
in the event of a supply voltage failure.
All LEDs are off.
The power supply does not switch over to the buffer
mode in the event of a supply voltage failure; the device
switches off. The rechargeable battery module is
charged when the supply voltage is reconnected, but the
device remains switched off until the remote shutdown is
activated.
The connected consumers are fed as long as the supply
voltage is available.
MINI-DC-UPS/12DC/4
PHOENIX CONTACT
12

Related parts for 2866598