SPBT2532C2.AT STMicroelectronics, SPBT2532C2.AT Datasheet - Page 41

IC BLUETOOTH VER 2.1 CLASS 2

SPBT2532C2.AT

Manufacturer Part Number
SPBT2532C2.AT
Description
IC BLUETOOTH VER 2.1 CLASS 2
Manufacturer
STMicroelectronics

Specifications of SPBT2532C2.AT

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
Bluetooth v2.1+EDR, Class 2 & 3
Applications
General Purpose
Power - Output
2dBm
Sensitivity
-85dBm
Voltage - Supply
2.8 V ~ 3.6 V
Data Interface
PCB, Surface Mount
Memory Size
256kB Flash, 48kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Wireless Frequency
2400 MHz to 2483.5 MHz
Interface Type
I2C, I2S, SPI, UART
Data Rate
2 Mbps
Modulation
AFH
Operating Voltage
2.8 V to 3.6 V
Antenna
Without Antenna
Board Size
10 mm x 13 mm
Operating Temperature Range
- 40 C to + 85 C
Output Power
4 mA
Security
128 bit Encryption
Technology/ Type
Class 2 Bluetooth Module
Processor Series
STLC2500
For Use With
497-10656 - BOARD DEMO BLUETOOTH SPBT2532C2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Transmitting
-
Current - Receiving
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Bluetooth Devices
Other names
497-10539

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPBT2532C2.AT
Manufacturer:
ST
0
Part Number:
SPBT2532C2.AT2
Manufacturer:
Broadchip
Quantity:
16 000
Part Number:
SPBT2532C2.AT2
Manufacturer:
ST
0
SPBT2532C2.AT
Appendix E
E.1
E.2
Appendix E details the error responses that occur under specific circumstances.
There are seven error responses that can occur beyond error responses specific to a
particular command (e.g., Discovery). They are:
The following subsections detail the different error responses. These error responses
replace the original error response
AT-AB ErrorCommand
ErrConnect
The ErrConnect error response will be sent if abSerial has a valid connection established
and the command cannot be executed while connected (even in the command mode).
Examples of commands that produce this error response are given in the following table.
Table 11.
ErrExecution
The ErrExecution error response will be sent if the command cannot complete for any
reason.
Examples of commands that produce this error response are given in the following table.
Table 12.
ErrConnect
ErrExecution
ErrFormat
ErrInvalidParam
ErrNumParam
ErrUnknownCmd
ErrInProgress
AT+AB SPPConnect
AT+AB discovery
00043e000000
AT+AB discovery
Example
Error responses
Example commands that generate <ErrConnect>
Example commands that generate <ErrExecution>
Example
Doc ID 16089 Rev 7
Performing a device discovery while a connection is up.
Establishing a connection to a device while a connection is exists
with another.
Execution of command with correct syntax failed
Reason
Reason
Error responses
41/50

Related parts for SPBT2532C2.AT