ATTINY461V-10PU Atmel, ATTINY461V-10PU Datasheet - Page 146

Microcontrollers (MCU) 4kB Flash 0.256kB EEPROM 16 I/O Pins

ATTINY461V-10PU

Manufacturer Part Number
ATTINY461V-10PU
Description
Microcontrollers (MCU) 4kB Flash 0.256kB EEPROM 16 I/O Pins
Manufacturer
Atmel
Datasheets

Specifications of ATTINY461V-10PU

Processor Series
ATTINY4x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
2-Wire/SPI/USI
Maximum Clock Frequency
10 MHz
Number Of Programmable I/os
16
Number Of Timers
2
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
On-chip Adc
11-ch x 10-bit
Program Memory Type
Flash
Program Memory Size
4 KB
Package / Case
PDIP-20
Package
20PDIP
Device Core
AVR
Family Name
ATtiny
Maximum Speed
10 MHz
Ram Size
256 Byte
Operating Temperature
-40 to 85 °C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY461V-10PU
Manufacturer:
ATMEL
Quantity:
6 223
146
ATtiny261/461/861
Figure 15-3. ADC Prescaler
When initiating a single ended conversion by setting the ADSC bit in ADCSRA, the conversion
starts at the following rising edge of the ADC clock cycle.
A normal conversion takes 13 ADC clock cycles. The first conversion after the ADC is switched
on (ADEN in ADCSRA is set) takes 25 ADC clock cycles in order to initialize the analog circuitry,
as shown in
Figure 15-4. ADC Timing Diagram, First Conversion (Single Conversion Mode)
The actual sample-and-hold takes place 1.5 ADC clock cycles after the start of a normal conver-
sion and 13.5 ADC clock cycles after the start of an first conversion. See
conversion is complete, the result is written to the ADC Data Registers, and ADIF is set. In Sin-
gle Conversion mode, ADSC is cleared simultaneously. The software may then set ADSC again,
and a new conversion will be initiated on the first rising ADC clock edge.
Cycle Number
ADC Clock
ADEN
ADSC
ADIF
ADCH
ADCL
Figure 15-4
1
2
MUX and REFS
Update
ADEN
START
below.
12
ADPS0
ADPS1
ADPS2
13
CK
14
15
Sample & Hold
16
Reset
First Conversion
17
7-BIT ADC PRESCALER
18
ADC CLOCK SOURCE
19
20
21
22
Conversion
Complete
23
24
25
Figure
Sign and MSB of Result
Next
Conversion
1
LSB of Result
15-5. When a
2588E–AVR–08/10
2
MUX and REFS
Update
3

Related parts for ATTINY461V-10PU