ULE-5/12-D24P-C Murata Power Solutions Inc, ULE-5/12-D24P-C Datasheet - Page 10

DC/DC Converters & Regulators 60W 24V to 5V 12A POSITVE POLARITY

ULE-5/12-D24P-C

Manufacturer Part Number
ULE-5/12-D24P-C
Description
DC/DC Converters & Regulators 60W 24V to 5V 12A POSITVE POLARITY
Manufacturer
Murata Power Solutions Inc
Series
ULEr
Type
Step Downr
Datasheets

Specifications of ULE-5/12-D24P-C

Output Power
60 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
12 A
Isolation Voltage
2.25 KV
Package / Case Size
Eighth Brick
Product
Isolated
Output Current
12A
Input Voltage
24V
Output Voltage
5V
Screening Level
Industrial
Product Length (mm)
58.4mm
Product Depth (mm)
22.9mm
Mounting Style
Through Hole
Pin Count
8
Package / Case
1/8-Brick
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ULE-5/12-D24P-C
*No derating is required up to 85°C.
See notes on page 11.
ISOLATION CHARACTERISTICS
MISCELLANEOUS CHARACTERISTICS
ULE-48/1.25-D48
ULE-48/1.25-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48*
Model Family
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-24/3-D48
Model Family
Calculated
MTBF
2250 min.,
dependent
TBC
Input to
Output
2000-
model
Min.
(V)
Operating Temperature Range
−40 to +85ºC with derating
Resistance
Isolation
(MΩ)
derating curves
100
See
Capacitance
Isolation
1750
1750
2000
1500
(pF)
470
Operating PCB
(no derating)
Safety Rating
Temperature
Insulation
Isolation
+105ºC
−40 to
Basic
www.murata-ps.com
Temperature
Storage
+125ºC
Range
−55 to
DYNAMIC CHARACTERISTICS
ULE-48/1.25-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
Model Family
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-24/3-D48
Protection/
Shutdown
dependent
Thermal
+125ºC,
+105 to
model
Current
150μSec to ±1.25% of fi nal value
150μSec to ±1.25% of fi nal value
150μSec to ±1.25% of fi nal value
Circuit
300mA
500mA
100μSec to ±1.5% of fi nal value
100μSec to ±1.5% of fi nal value
100μSec to ±1.5% of fi nal value
100μSec to ±1.5% of fi nal value
150μSec to ±1.5% of fi nal value
Short
0.65A
80μSec to ±1.5% of fi nal value
150μSec to ±1% of fi nal value
150μSec to ±1% of fi nal value
100μSec to ±1% of fi nal value
200μSec to ±2% of fi nal value
200μSec to ±1% of fi nal value
75μSec to ±2% of fi nal value
75μSec to ±2% of fi nal value
3A
3A
3A
3A
3A
3A
3A
3A
5A
5A
2A
3A
3A
Dynamic Load Response
(50-75-50% load step)
Isolated, High Density, Eighth-Brick
via magnetic
Overvoltage
Protection
11 May 2011
feedback
1.25–20 Amp, DC/DC Converters
3.96
3.96
3.96
15.0
14.0
28.0
55.0
(V)
2.3
2.0
2.3
2.3
3.5
3.0
6.0
6.0
6.4
12
Method
Short Circuit
overload for
autorestart.
Protection
recovery
limiting,
Remove
Current
hiccup
MDC_ULE Series.E01 Page 10 of 26
email: sales@murata-ps.com
ULE Series
Frequency
Switching
Short Circuit
280±15
280±15
340±15
340±15
385±15
385±45
310±15
385±15
365±15
325±15
450±15
450±15
400±15
380±15
240±30
250±15
No damage.
Continuous,
Duration
shorted to
KHz
ground.
output
16
+85ºC/85%
condensing
Humidity
Relative
non-
To

Related parts for ULE-5/12-D24P-C