ULE-5/12-D24P-C Murata Power Solutions Inc, ULE-5/12-D24P-C Datasheet - Page 11

DC/DC Converters & Regulators 60W 24V to 5V 12A POSITVE POLARITY

ULE-5/12-D24P-C

Manufacturer Part Number
ULE-5/12-D24P-C
Description
DC/DC Converters & Regulators 60W 24V to 5V 12A POSITVE POLARITY
Manufacturer
Murata Power Solutions Inc
Series
ULEr
Type
Step Downr
Datasheets

Specifications of ULE-5/12-D24P-C

Output Power
60 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
12 A
Isolation Voltage
2.25 KV
Package / Case Size
Eighth Brick
Product
Isolated
Output Current
12A
Input Voltage
24V
Output Voltage
5V
Screening Level
Industrial
Product Length (mm)
58.4mm
Product Depth (mm)
22.9mm
Mounting Style
Through Hole
Pin Count
8
Package / Case
1/8-Brick
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ULE-5/12-D24P-C
1. All models are tested and specifi ed with external 1||10 μF ceramic/tantalum output
2. Input Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input
3. Note that Maximum Power Derating curves indicate an average current at nominal
4. Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1,
5. The On/Off Control is normally controlled by a switch. But it may also be driven with
6. Short circuit shutdown begins when the output voltage degrades approximately 2%
7. The outputs are not intended to sink appreciable reverse current..
8. Output noise may be further reduced by adding an external fi lter. See I/O Filtering
PHYSICAL CHARACTERISTICS AND SAFETY
Outline dimensions
Pin material
Pin diameter
Pin fi nish
Weight
Electromagnetic interference (external fi lter required)
Safety
PERFORMANCE SPECIFICATION NOTES
capacitors and a 22 μF external input capacitor. All capacitors are low ESR types.
These capacitors are necessary to accommodate our test equipment and may
not be required to achieve specifi ed performance in your applications. All models
are stable and regulate within spec under no-load conditions. General conditions
for Specifi cations are +25 deg.C, V
airfl ow must be supplied for extended testing under power.
fi ltering is C
input voltage. At higher temperatures and/or lower airfl ow, the DC/DC converter will
tolerate brief full current outputs if the total RMS current over time does not exceed
the Derating curve. All Derating curves are presented at sea level altitude. Be aware
of reduced power dissipation with increasing density altitude.
Case 3, ground fi xed conditions, Tpcboard=+25ºC, full output load, natural air convection.
external logic or by applying appropriate external voltages which are referenced to
Input Common. The On/Off Control Input should use either an open collector or open
drain transistor.
from the selected setting.
and Noise Reduction.
IN
=33 μF tantalum, C
BUS
IN
=220 μF electrolytic, L
=nominal, V
OUT
=nominal, full load. Adequate
BUS
=12 μH.
www.murata-ps.com
10. Regulation specifi cations describe the deviation as the line input voltage or output
11. Alternate pin length and/or other output voltages are available under special quantity
12. Electronic overvoltage shutdown is not included on 48V input models to comply
13. Do not exceed maximum power specifi cations when adjusting the output trim.
14. At zero output current, the output may contain low frequency components which
15. If reverse polarity is accidentally applied to the input, a body diode will become
16. Output current limit is non-latching. When the overcurrent fault is removed, the
17. The Sense inputs are not included on lower current output models.
18. ULE-12/4.2-D24 minimum load is 0.42 Amps (10%) for rated specifi cations.
19. ULE-5/12-D24 I
20. ULE-12/4.2-D48 has no surface mount option.
21. Full load conditions, see ordering guide.
See mechanical specs (below)
Copper alloy
0.04/0.062" (1.016/1.524mm)
Nickel underplate with gold overplate
1 ounce (28 grams)
Designed to meet EN55022/CISPR22 with external fi lter
Certifi ed to UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1, 2nd edition
9. All models are fully operational and meet published specifi cations, including “cold
start” at –40ºC.
load current is varied from a nominal midpoint value to either extreme.
order.
with certain telecom reliability requirements. These requirements attempt continued
operation despite input overvoltage. The converter is rated only to the maximum
input voltage.
exceed the ripple specifi cation. The output may be operated indefi nitely with no load.
forward biased and will conduct considerable current. To ensure reverse input
protection with full output load, always connect an external input fuse in series with
the +V
input voltage.
converter will immediately recover.
IN
input. Use approximately twice the full input current rating with nominal
OUT
=8A max. if V
Isolated, High Density, Eighth-Brick
11 May 2011
1.25–20 Amp, DC/DC Converters
IN
=19-20V.
MDC_ULE Series.E01 Page 11 of 26
email: sales@murata-ps.com
ULE Series