H3DE-M2AC/DC24-230 Omron, H3DE-M2AC/DC24-230 Datasheet - Page 20

Stopwatches / Timers MULTI-FUN SOLID STAT

H3DE-M2AC/DC24-230

Manufacturer Part Number
H3DE-M2AC/DC24-230
Description
Stopwatches / Timers MULTI-FUN SOLID STAT
Manufacturer
Omron
Type
Multifunctionr

Specifications of H3DE-M2AC/DC24-230

Timing Range
0.1 s to 120 Hrs
Supply Voltage
25 VAC to 230 VAC, 24 VDC to 28 VDC
Accuracy
+/- 1 %
Current Rating (max)
5 A
Display Type
Hand Dial
Operating Temperature Range
- 10 C to + 55 C
Termination Style
Screw
Time Range
0.1 Sec. To 120 Hr.
Supply Voltage Max
230VDC
Time Range Max
120h
Switch Function
DPDT
Time Range Min
0.1s
Supply Voltage Min
24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
J I/O FUNCTION
J BASIC OPERATION
Time Unit Selection
The time unit display window for output ON is located on the
upper-right side of the front panel, above the corresponding time
unit selector.
The time unit display window for output OFF is located on the
lower-right side of the front panel below the corresponding time
unit selector.
According to the setting of each time unit selector, “sec” for
seconds, “10s” for 10 seconds, “min” for minutes, or “hrs” for
hours will appear in the corresponding time unit display window.
J TIMING CHARTS
Note: 1. The reset time requires a minimum of 0.1 s.
Inputs
Outputs
Operating Mode
OFF-Start
Power (A
Output relay: NO
15 and 18
(ON indicator)
Output relay: NC
15 and 16
OFF indicator
2. When power is supplied in flicker-ON start mode, the OFF indicator lights momentarily, but this has no effect on the
1
and A
performance of the Timer.
2
)
Control output
ON
OFF
ON
OFF
ON
OFF
ON
OFF
t
t
ON
OFF
: ON set time
Outputs are turned ON/OFF according to the time set by the ON-time/OFF-time setting dial.
: OFF set time
OFF-time unit display window
OFF-time unit selector (select
one from s, 10s, min, or h)
ON-time unit display window
ON-time unit selector (select
one from s, 10s, min, or h)
0.1 s min.
ON-Start
Power (A
Output relay: NO
15 and 18
(ON indicator)
Output relay: NC
15 and 16
Time Scale Selection
The time scale selector on the upper-left side of the front panel
can be set to 0.1 or 1 as a magnification coefficient.
Time Setting
Use the ON/OFF-time setting dials to set the ON/OFF time.
OFF indicator
Time scale display window
Time scale selector
1
and A
2
)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
t
t
ON
OFF
: ON set time
: OFF set time
setting dial
OFF-time
setting dial
ON-time
0.1 s min.