Specifications of H3DE-M2AC/DC24-230

Timing Range
0.1 s to 120 Hrs
Supply Voltage
25 VAC to 230 VAC, 24 VDC to 28 VDC
Accuracy
+/- 1 %
Current Rating (max)
5 A
Display Type
Hand Dial
Operating Temperature Range
- 10 C to + 55 C
Termination Style
Screw
Time Range
0.1 Sec. To 120 Hr.
Supply Voltage Max
230VDC
Time Range Max
120h
Switch Function
DPDT
Time Range Min
0.1s
Supply Voltage Min
24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
J MOUNTING CLEARANCE
If the load current is continuously being supplied to the Timer for
a long period of time, be sure to provide the mounting clearance
as shown in the figure below. If used under conditions without
this mounting clearance, an excessive rise in the internal
temperature of the components may result in a shortened
component life.
J SWITCHING CURRENT VS.
8
Note: Measurement Condition: Input voltage of 230 VAC.
70
60
50
40
30
20
AMBIENT TEMPERATURE
(WHEN MOUNTING TWO OR MORE
H3DE UNITS SIDE-BY-SIDE)
0
H3DE
1
t
2
H3DE
t: Mounting clearance (mm)
3
4
t
H3DE
5
Mounting
clearance: 5 mm
Mounting clearance:
50 mm min.
Mounting
clearance: 10 mm
Mounting
clearance: 0 mm
Load current (A)
Maximum range of
operating ambient
temperature
DIN track
J INPUT/OUTPUT
Relationship Between Input and
Power Supply Circuits
Since the input circuit and the power supply circuit are
configured independently, the input circuit can be turned on or off
irrespective of the on/off state of the power supply. Note that a
voltage equivalent to the power supply voltage is applied to the
input circuit.
A Relay or Transistor as an External
Signal Input Device
When connecting a relay or a transistor as an external signal
input device, consider the following points (exemplified in the
diagrams that follow) to prevent short-circuiting due to a sneak
current to the transformerless power supply.
If a relay or transistor is connected to two or more Timers, the
input terminals of those Timers must be wired properly so that
they will not be different in phase, or the terminals will be
short-circuited to one another (refer to the figures below).
The H3DE Series is provided with a transformerless power
supply system.
AC/DC
power
supply
Incorrect
Correct
Short-circuit
current
Short-circuit
current
Input circuit
Contact or transistor for
external input signal
Contact or transistor for
external input signal
B1
B1
B1
A2
Power supply
circuit
B1
B1
H3DE
H3DE
A1
H3DE
H3DE
A1
A2
A1
A2
A1
A2
A1
A2
supply
Power
supply
Power