H3DE-M2AC/DC24-230 Omron, H3DE-M2AC/DC24-230 Datasheet - Page 3

Stopwatches / Timers MULTI-FUN SOLID STAT

H3DE-M2AC/DC24-230

Manufacturer Part Number
H3DE-M2AC/DC24-230
Description
Stopwatches / Timers MULTI-FUN SOLID STAT
Manufacturer
Omron
Type
Multifunctionr

Specifications of H3DE-M2AC/DC24-230

Timing Range
0.1 s to 120 Hrs
Supply Voltage
25 VAC to 230 VAC, 24 VDC to 28 VDC
Accuracy
+/- 1 %
Current Rating (max)
5 A
Display Type
Hand Dial
Operating Temperature Range
- 10 C to + 55 C
Termination Style
Screw
Time Range
0.1 Sec. To 120 Hr.
Supply Voltage Max
230VDC
Time Range Max
120h
Switch Function
DPDT
Time Range Min
0.1s
Supply Voltage Min
24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Specifications
J GENERAL
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.
J TIME RANGES
Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.
J RATINGS
Note: 1. DC ripple rate: 20% max.
Item
Operating mode
Terminal block
Terminal screw tightening
torque
Input type
Output type
Mounting method
Attachment
Approved standards
Time scale display
x 0.1
x 1
Rated supply voltage
(See Notes 1 and 2.)
Operating voltage range
Power reset
Reset voltage
Power
consumption
(S
(See Note 3.)
Voltage input
Control output
Ambient temperature
Ambient humidity
2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning
3. The power consumption is for mode A (ON-delay) after the Timer counts the time-up time and for the AC input at 50 Hz. The
N t 3 )
p
on or off the power supply to the Timer with a solid-state output such as a sensor.
power consumption of the H3DE-Mj includes the input circuit with the B1 and A1 terminals short-circuited.
H3DE-M1
H3DE-M2
H3DE-S1
H3DE-S2
Time unit display
seconds
0.1 to 1.2 s
1 to 12 s
H3DE-M2
A: ON-delay (Signal or Power)
B: Repeat-cycle OFF start (Signal or Power)
B2: Repeat-cycle ON start (Signal or Power)
C: Signal ON-/OFF-delay
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON-/OFF-delay
J: One-shot (Signal or Power)
Clamps two 2.5 mm
0.98 N S m max. {approx. 10 kgf S cm max.}
Voltage input
Relay: DPDT
DIN track mounting (See Note.)
Nameplate
UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
24 to 230 VAC/DC (50/60 Hz)
12 VDC (H3DE-M2 model only)
85% to 110% of rated supply voltage
Minimum power-off time: 0.1 s
2.4 VAC/DC max.
AC: approx. 4.3 VA (2.2 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 4.8 VA (2.4 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
AC: approx. 2.7 VA (1.6 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 3.2 VA (1.9 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
Max. permissible capacitance between input lines (terminals B1 and A2) : 2000 pF
Load connectable in parallel with inputs (terminals B1 and A2)
H-level: 20.4 to 253 VAC/DC
L-level: 0 to 2.4 VAC/DC
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1); 5 A at 30 VDC with resistive
load (cosφ = 1)
Operating: - -10°C to 55°C (14 to 131°F) with no icing
Storage: - -25°C to 65°C (- -13°F to 149°F) with no icing
Operating: 35% to 85%
2
max. bar terminals without sleeves.
min
0.1 to 1.2 min
1 to 12 min
H3DE-M1
Relay: SPDT
hrs
0.1 to 1.2 h
1 to 12 h
H3DE-S2
A: ON-delay
B2: Repeat-cycle ON start
E: Interval
J: One-shot
---
Relay: DPDT
10 h
1 to 12 h
10 to 120 h
H3DE-S1
Relay: SPDT