H3DE-M2AC/DC24-230 Omron, H3DE-M2AC/DC24-230 Datasheet - Page 44

Stopwatches / Timers MULTI-FUN SOLID STAT

H3DE-M2AC/DC24-230

Manufacturer Part Number
H3DE-M2AC/DC24-230
Description
Stopwatches / Timers MULTI-FUN SOLID STAT
Manufacturer
Omron
Type
Multifunctionr

Specifications of H3DE-M2AC/DC24-230

Timing Range
0.1 s to 120 Hrs
Supply Voltage
25 VAC to 230 VAC, 24 VDC to 28 VDC
Accuracy
+/- 1 %
Current Rating (max)
5 A
Display Type
Hand Dial
Operating Temperature Range
- 10 C to + 55 C
Termination Style
Screw
Time Range
0.1 Sec. To 120 Hr.
Supply Voltage Max
230VDC
Time Range Max
120h
Switch Function
DPDT
Time Range Min
0.1s
Supply Voltage Min
24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
J INPUT WIRES
The input wires must be as short as possible. If the floating
capacity of wires exceeds 2,000 pF (approx. 17 m for cables with
120 pF/m), the operation will be affected. This is particularly
important to note when using shielded cables.
J VDE CONFORMANCE
The H3DE as a built-in timer conforms to VDE 0435/P2021
provided that the following conditions are satisfied:
The output section of the H3DE is provided only with basic
isolation. To ensure reinforced isolation required by the VDE
standards, provide supplementary basic isolation on the load side
connected to the output.
The H3DE itself is designed according to the following:
The following facts are based on the above standards:
J ENVIRONMENT
When using the Timer in an area with excess electronic noise,
separate the Timer, wiring, and the equipment which generates
the input signals as far as possible from the noise sources. To
further prevent electronic interference, shield the input signal
wiring.
Organic solvents (such as paint thinner), as well as very acidic or
basic solutions, can damage the outer casing of the Timer.
Do not use the Timer in places where it is exposed to dust,
corrosive gas, or direct sunlight.
When storing the Timer, ensure that the ambient temperature and
humidity are within the rated values. Leave the Timer at room
temperature for at least three hours before using the Timer if it
has been stored at an ambient temperature of - -10°C or below.
Cat. No. GC TMCN1
1-800-55-OMRON
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
Overvoltage category III
Pollution degree 2
Operation parts on the front and bottom: Reinforced isola-
tionwith clearance of 5.5 mm and creepage distance of 5.5
mm at 230 VAC
Output: Basic isolation with clearance of 3 mm and creepage
distance of 3 mm at 230 VAC
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
3/02
OMRON ON- -LINE
Global - - http://www.omron.com
USA - - http://www.omron.com/oei
Canada - - http://www.omron.com/oci
Specifications subject to change without notice.
J RELAY LIFE EXPECTANCY
Built-in relay for the H3DE: G6RN; 50,000 operations min.
(8 A at 250 VAC, resistive load at 360 operations/h.)
OMRON CANADA, INC.
416-286-6465
885 Milner Avenue
Scarborough, Ontario M1B 5V8