ADXL180WCPZ-RL Analog Devices Inc, ADXL180WCPZ-RL Datasheet - Page 14

IC ACCELEROMETER CONFIG 16-LFCSP

ADXL180WCPZ-RL

Manufacturer Part Number
ADXL180WCPZ-RL
Description
IC ACCELEROMETER CONFIG 16-LFCSP
Manufacturer
Analog Devices Inc
Series
iMEMS®r
Datasheet

Specifications of ADXL180WCPZ-RL

Axis
X or Y
Acceleration Range
±50g, 100g, 150g, 200g, 250g, 350g, 500g
Voltage - Supply
5 V ~ 14.5 V
Output Type
Analog
Bandwidth
100Hz ~ 800Hz Selectable
Mounting Type
Surface Mount
Package / Case
16-LFQFN, CSP Exposed Pad
Package Type
LFCSP EP
Operating Supply Voltage (min)
5V
Operating Temperature (min)
-40C
Operating Temperature (max)
125C
Operating Temperature Classification
Automotive
Product Depth (mm)
5mm
Product Height (mm)
1.43mm
Product Length (mm)
5mm
Mounting
Surface Mount
Pin Count
16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Interface
-
Lead Free Status / Rohs Status
Compliant
Other names
ADXL180WCPZ-RLCT
ADXL180
MANCHESTER DATA ENCODING
To encode data within the current modulation, the ADXL180
uses Manchester encoding. Manchester encoding works on the
principle of transitions representing binary 1s and 0s, as shown
in Figure 8. Manchester encoding uses a set of predefined start
bits to transmit the clocking within each message, see Figure 9.
The pattern of the start bits allows the receiver to synchronize
itself to the bit stream. These start bits are user selectable.
BUS
CURRENT
BUS
CURRENT
Figure 8. Manchester-1, Start Bits and Phase
I
I
I
I
SIG
IDLE
SIG
IDLE
Figure 9. Manchester-2, Bit Coding
LOGIC 1
LOGIC 0
START BITS
START BITS
LOGIC 0
LOGIC 0
LOGIC 0 LOGIC 1
LOGIC 0 LOGIC 1
Rev. A | Page 14 of 60
Table 6. MAN Options
MAN
0
1
The phase of the Manchester encoded data can be selected via
a bit in the configuration registers. See Figure 8 and Figure 9
for details. The configuration bit that sets the phase of the Man-
chester encoder also sets the value of the two start bits. The start
bits are 1, 0 for Manchester-1 and 0, 0 for Manchester-2. For
phase and start bit information, see Table 6.
OPERATION AT LOW V
The ADXL180 monitors its internal regulator voltage to ensure
proper operation. If the bus voltage drops, or the internal regu-
lator voltage drops below the V
resets. See the Voltage Regulator Monitor Reset Operation
section.
OPERATION AT HIGH V
If the regulator pin detects a high voltage, such as from a
short or leakage condition, the ADXL180 detects an error.
See the Voltage Regulator Monitor Reset Operation section
for more details.
Manchester
Coding
Manchester-1
(Default)
Manchester-2
Start
Bits
1, 0
0, 0
BP
DD
PUR
OR LOW V
reset threshold, the device
Logic 0
Falling edge
Rising edge
DD
Logic 1
Rising edge
Falling edge

Related parts for ADXL180WCPZ-RL