C500DA101 Omron, C500DA101 Datasheet - Page 101

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
86
Memory Map
R/W
R/W
R
R
R/W
Read/
write
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
map word
Memory
00 to 15
00 to 15
00 to 15
00 to 06
00 to 15
Bits
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
---
---
---
Input
point
Averaging sample count
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
Scaling low limit
Scaling high limit
EEPROM write count
EEPROM error flags
EEPROM compare word
Function
These words contain the number of
Unit conversions to average before
reporting conversion data to words 01
to16. The values are in number of
samples.
Valid values are BCD 0001 to 9999
and binary 0001 to 7FFF. The default
value is 0020 BCD. The averaging
function is performed prior to the data
being placed in the conversion data
words (01 through 16).
These words contain the scaling low
and high limits for each input point.
The values are in engineering units.
The default values are 0000 for the
low limit and 4095 for the high limit.
The scaling function is performed
prior to the data being placed in the
conversion data words (0 to16).
This word contains the current
number of write operations that have
been executed for the EEPROM.
This word contains error flags used
during the EEPROM write operation.
This word is set by the user to
confirm that an EEPROM write
operation should occur. This is a
safety to prevent erroneous writes
from occurring and damaging the
EEPROM chip.
Description
Section
5-5

Related parts for C500DA101