C500DA101 Omron, C500DA101 Datasheet - Page 183

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
172
Data Exchange with CPU Unit
Words
41
42
43
44
45
46
47
48
0 to 15 1
0 to 15
0 to 15 2
0 to 15
0 to 15 3
0 to 15
0 to 15 4
0 to 15
Bits
Output
points
Output Lower
Limit for Output
Point 1
Output Upper
Limit for Output
Point 1
Output Lower
Limit for Output
Point 2
Output Upper
Limit for Output
Point 2
Output Lower
Limit for Output
Point 3
Output Upper
Limit for Output
Point 3
Output Lower
Limit for Output
Point 4
Output Upper
Limit for Output
Point 4
Name
Output lower limit for output
point 1. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 1. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output lower limit for output
point 2. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 2. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output lower limit for output
point 3. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 3. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output lower limit for output
point 4. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 4. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Description
With No Scaling
BCD:
0 to 4095
(0000 to 4095
or
or
–2048 to 2048
(A048 to 2048
Binary:
0000 to 0FFF
or
or
F800 to 07FF
With Scaling
BCD:
–7999 to 7999
(F999 t 7999
(F999 to 7999
Binary:
–32767 to 32767
(8001 to 7FFF
Be sure to set
Be sure to set
values within the
allowable range
regardless of
whether the
upper/lower limit
upper/lower limit
function is
enabled. If values
outside the range
are set, the
Upper/Lower Limit
Over Flag and
Over Flag and
other related flags
may turn ON.
Data
Hex
Hex
Hex
Hex
Hex
Hex
)
)
)
)
)
Lower
limit:
0000
Upper
limit:
4095
4095
Default
Section
Hex
Hex
Write: W
R/W
Read: R
9-3