C500DA101 Omron, C500DA101 Datasheet - Page 181

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
170
Data Exchange with CPU Unit
Words
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
0 to 15 1
0 to 15
0 to 15 2
0 to 15
0 to 15 3
0 to 15
0 to 15 4
0 to 15
0 to 15 5
0 to 15
0 to 15 6
0 to 15
0 to 15 7
0 to 15
0 to 15 8
0 to 15
Bits
Output
points
Scaling Lower
Limit for Output
Point 1
Scaling Upper
Limit for Output
Point 1
Scaling Lower
Limit for Output
Point 2
Scaling Upper
Limit for Output
Point 2
Scaling Lower
Limit for Output
Point 3
Scaling Upper
Limit for Output
Point 3
Scaling Lower
Limit for Output
Point 4
Scaling Upper
Limit for Output
Point 4
Scaling Lower
Limit for Output
Point 5
Scaling Upper
Limit for Output
Point 5
Scaling Lower
Limit for Output
Point 6
Scaling Upper
Limit for Output
Point 6
Scaling Lower
Limit for Output
Point 7
Scaling Upper
Limit for Output
Point 7
Scaling Lower
Limit for Output
Point 8
Scaling Upper
Limit for Output
Point 8
Name
Scaling lower limit for output
point 1. Set in engineering
units.
Scaling upper limit for output
point 1. Set in engineering
units.
Scaling lower limit for output
point 2. Set in engineering
units.
Scaling upper limit for output
point 2. Set in engineering
units.
Scaling lower limit for output
point 3. Set in engineering
units.
Scaling upper limit for output
point 3. Set in engineering
units.
Scaling lower limit for output
point 4. Set in engineering
units.
Scaling upper limit for output
point 4. Set in engineering
units.
Scaling lower limit for output
point 5. Set in engineering
units.
Scaling upper limit for output
point 5. Set in engineering
units.
Scaling lower limit for output
point 6. Set in engineering
units.
Scaling upper limit for output
point 6. Set in engineering
units.
Scaling lower limit for output
point 7. Set in engineering
units.
Scaling upper limit for output
point 7. Set in engineering
units.
Scaling lower limit for output
point 8. Set in engineering
units.
Scaling upper limit for output
point 8. Set in engineering
units.
Description
BCD:
–7999 to 7999
(F999 to 7999
(
Binary:
–32767 to 32767
(8001 to 7FFF
(8001 to 7FFF
Be sure to set
values within the
allowable range
allowable range
regardless of
whether the
scaling function is
enabled If values
enabled. If values
outside the range
are set, the Invalid
Data Received
Data Received
Flag and other
related flags may
turn ON.
turn ON.
Data
Hex
Hex
Hex
Hex
)
)
)
)
Lower
limit:
0000
U
Upper
limit:
4095
Default
Section
Hex
Hex
Hex
Write: W
R/W
Read: R
9-3