Function Blocks (Unit Ver. 3.5)
Note: 1. High-speed control of function blocks is supported (the operation cycle can be set to 0.01 s, 0.02 s, or 0.05 s), except when using the
Signal Selection/
Switching
ITEM Settings
Pulse Train Opera-
tion
Others
Sequence Opera-
tion
Contact Type Con-
trol Target
2. Cannot be used with the CS1W-LCB05-GTC.
3. LCB05D not supported.
4. Supported by the CS1W-LC001 only.
5. Supported by the CS1W-LCB01/05 only.
Type
LCB05D.
3-output Selector
(See note 1.)
Constant Selector
(See note 1.)
Constant Generator
(See note 1.)
Ramped Switch
Bank Selector
(See note 3.)
Split Converter
(See note 3.)
Constant ITEM Setting
(See note 1.)
Variable ITEM Setting
(See note 1.)
Batch Data Collector
(See note 1.)
Accumulated Value Input
Adder
Accumulated Value Analog
Multiplier
Accumulator for Accumu-
lated Value Input
Contact input/Accumulated
Value Output
Accumulated Value Input/
Contact Output
Analog/Pulse Width Con-
verter (See note 1.)
Contact Distributor
Constant Comparator
(See note 1.)
Variable Comparator
(See note 1.)
Timer (See note 1.)
ON/OFF Timer
(See note 1.)
Clock Pulse (See note 1.)
Counter (See note 1.)
Internal Switch
(See note 1.)
Level Check (See note 1.) Checks an analog input for 8 levels and outputs a contact corresponding to the level. The level
ON/OFF Valve Manipulator Manipulates and monitors ON/OFF valves with open/close limit switches.
Motor Manipulator
Reversible Motor Manipu-
lator
Motor Opening Manipulator Inputs a target opening, and manipulates an electric positional-proportional motor.
Switch Meter
(See note 2.)
Block Name
Stores each of max. 8 analog inputs to buffer by a certain timing within sequential processing.
Adds up to four accumulated value signals.
Multiplies analog signals by the accumulated value signals.
Converts 4-digit accumulated value signals to 8 digits.
Counts low-speed contact pulses, and outputs 8-digit accumulated signals.
Converts 4-digit accumulated value signals to low-speed contact pulses before they are output.
Changes the ON/OFF duration ratio in a constant cycle duration so that it is proportional to the
analog signal.
Connect contact signals between function blocks in a 1:1 connection.
Compares up to eight sets of analog signals and constants, and outputs the comparison results
as contacts.
Compares up to eight pairs of analog signals, and outputs the comparison results as contacts.
2-stage output type addition timer for forecast values and reached values. Can also output the
present value.
Timer for performing ON-OFF operation at preset ON and OFF times.
Manipulates and monitors ON/OFF valves with open/close limit switches.
current value.
Temporary storage contact for accepting relays in the Step Ladder Program block.
(Note: One internal switch is already allocated as “temporary storage” in CX-Process Tool.)
number is also output as an analog value.
Manipulates and monitors reversible motor operation.
Manipulates and monitors multiple (up to 8) devices such as ON/OFF valves, motors, or pumps.
Outputs one analog input signal in one of three switched directions.
Selects 8 preset constants by the contact signal.
Outputs 8 independent constants.
Switches two analog inputs (or constants) with a ramp.
Stores a maximum of eight sets of PID parameters (SP, P, I, D, MH, ML) in advance, and switch-
es them to basic PID, advanced PID, or blended PID parameters in response to the analog input
zone or input bit.
Takes an operating amount input from a basic PID or advanced PID block and converts the V
characteristics or parallel characteristics into two analog outputs (e.g., heating and cooling op-
erating amounts).
Writes the constant to the specified ITEM at the rising edge of the send command contact.
Writes the analog signal to the specified ITEM at the rising edge of the send command contact.
2-stage output type addition timer for forecast values and arrival values. Can also output the
Manipulates and monitors motor operation.
Function
Operation Blocks
19