CS1W-BAT01 Omron, CS1W-BAT01 Datasheet - Page 21

no-image

CS1W-BAT01

Manufacturer Part Number
CS1W-BAT01
Description
"BATTERY,CPU,CS1 SERIES ONLY"
Manufacturer
Omron
Datasheets

Specifications of CS1W-BAT01

Rohs Compliant
YES
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Function Blocks (Unit Ver. 3.5)
Note: High-speed control of function blocks is supported (the operation cycle can be set to 0.01 s, 0.02 s, or 0.05 s), except when using the
Node Terminal Blocks
CPU Unit Terminal Blocks
Analog I/O
Send to Computer
Send to All Nodes
Receive from All
Nodes
CPU Unit Terminals
LCB05D.
Type
Type
Type
AI 8-point Terminal
(PTS55) (See note.)
AI 8-point Terminal
(PTS56) (See note.)
AI 8-point Terminal
(PDC55) (See note.)
AI 4-point/AO 4-point
(See note.)
AI 16-point Terminal
(AD161) (See note.)
AI 8-point Terminal
(AD081) (See note.)
AO 8-point Terminal
(DA08V/C) (See note.)
AI 4-point Terminal
(AD041) (See note.)
AO 4-point Terminal
(DA041) (See note.)
AI 4-point Terminal (DRT1-
AD04) (See note.)
AO 2-point Terminal
(DRT1-DA02) (See note.)
DO to Computer
AO to Computer
1-Block Send Terminal to
Computer
4-Block Send Terminal to
Computer
DO Terminal to All Nodes
AO Terminal to All Nodes
DO Terminal Settings from
Computer
AO Terminal Settings from
Computer
DI Terminal from All Nodes Receives 32 contacts sent from nodes on the Controller Link Data Link.
AI Terminal from All Nodes Receives 2 analog values sent from nodes on the Controller Link Data Link.
Terminal (MAD44)
DI Terminal from CPU Unit Inputs max. 128 points from any leading address in CPU Unit I/O memory (one of CIO, WR,
DO Terminal to CPU Unit
AI Terminal from CPU Unit Inputs max. 8 words from any leading address in CPU Unit I/O memory (one of CIO, WR, HR,
AO Terminal to CPU Unit
Block Name
Block Name
Block Name
Inputs 8 analog signals from CS1W-PTS55 (isolated-type thermocouple Input Unit).
Inputs 8 analog signals from CS1W-PTS56 (isolated-type thermocouple Input Unit).
Inputs 8 analog signals from CS1W-PDC55 (Direct current Input Unit).
Inputs and outputs 4 analog signals each from the CS1W-MAD44.
Inputs 16 analog signals from CS1W-AD161.
Inputs 8 analog signals from the CS1W-AD081(-V1) or CJ1W-AD081(-V1).
Outputs 8 analog signals from the CS1W-DA08V/C or CJ1W-DA08V/C.
Inputs 4 analog signals from the CS1W-AD041(-V1) or CJ1W-AD041(-V1).
Outputs 4 analog signals from the CS1W-DA041 or CJ1W-DA041.
Inputs four analog signals from a DRT1-AD04 DeviceNet Slave Analog Input Unit.
Input Unit.
Outputs two analog signals from a DRT1-DA02 DeviceNet Slave Analog Output Unit.
Sends 128 contacts to the send-to-computer area. When CX-Process Monitor is used, the con-
tact signals to be monitored are connected to this function block.
Sends 16 analog values to the send-to-computer area. When CX-Process Monitor is used, the
analog signals to be monitored are connected to this function block.
Sends a specified 1 block to the send-to-computer area. When CX-Process Monitor is used, the
1 block to be monitored are connected to this function block.
Sends a specified 4 block to the send-to-computer area. When CX-Process Monitor is used, the
4 block to be monitored are connected to this function block.
Sends 32 contacts to nodes on the Controller Link Data Link.
Sends 2 analog values to nodes on the Controller Link Data Link.
Receives 32 contacts sent from the computer. (Can also be downloaded to the send-to-all
nodes area.)
Receives 2 analog values sent from the computer. (Can also be downloaded to the send-to-all
nodes area.)
HR, DM and EM area types). (read)
Outputs max. 128 points from any leading address in CPU Unit I/O memory (one of CIO, WR,
HR, DM and EM area types). (read and write)
DM and EM area types). (read)
Outputs max. 8 words from any leading address in CPU Unit I/O memory (one of CIO, WR,
HR, DM and EM area types). (read and write)
Function
Function
Function
Node Terminal Blocks
21