IP20 SOLA HEVI DUTY, IP20 Datasheet - Page 34

Fuse Cover Kit

IP20

Manufacturer Part Number
IP20
Description
Fuse Cover Kit
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of IP20

Peak Reflow Compatible (260 C)
No
Kit Contents
2 Covers And Thread Forming Screws
Leaded Process Compatible
No
For Use With
SBE Fuse Block
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IP2000-06
Manufacturer:
IR
Quantity:
20 000
Part Number:
IP2001
Manufacturer:
IOR
Quantity:
317
Part Number:
IP2001
Manufacturer:
International Rectifier
Quantity:
10 000
Part Number:
IP2001
Manufacturer:
IR
Quantity:
20 000
Part Number:
IP2001PBF
Manufacturer:
International Rectifier
Quantity:
10 000
Part Number:
IP2001TR
Manufacturer:
IR
Quantity:
1 000
Part Number:
IP2001TR
Manufacturer:
SMD
Quantity:
150
Part Number:
IP2001TR
Manufacturer:
International Rectifier
Quantity:
10 000
Part Number:
IP2001TR
Manufacturer:
IR
Quantity:
20 000
Part Number:
IP2001TRPBF
Manufacturer:
International Rectifier
Quantity:
10 000
Part Number:
IP2002
Manufacturer:
IOR
Quantity:
512
Part Number:
IP2002
Manufacturer:
OKITA
Quantity:
107
Part Number:
IP2002
Manufacturer:
International Rectifier
Quantity:
10 000
Part Number:
IP2003
Manufacturer:
IR
Quantity:
20 000
Part Number:
IP2003AP
Manufacturer:
IR
Quantity:
20 000
11.2
11.2.1 S4KPAD-CEHW-MBS - Manual Bypass Switch
AC Power Connections
Power connections may be disconnected from the UPS cabinet via a removable distribution box. This
may be a convenient feature if the UPS must be moved a short distance or replaced. This box allows
power connections to be conveniently disconnection from the main UPS cabinet. A label is attached to
the UPS to describe these procedures.
Hardwire and Hardwire/Receptacle boxes that include a Manual Bypass Switch allow AC power to
continue to flow from the mains input to the load while the box is removed from the UPS.
Disconnect
1. DO NOT turn off the branch circuit breaker feeding power the box unless you intend to disconnect
2. Ensure that the Maintenance Bypass Lamp is ON.
3. Switch to the maintenance bypass position.
4. Turn off the UPS using the front panel controls.
5. Turn off the UPS input circuit breaker on the box at the rear of the UPS.
6. Turn off the output circuit breaker on the rear of the UPS.
7. Remove the distribution box from the UPS
Reconnect
1. Align connectors and press the box onto the rear of the UPS.
2. Hold the box firmly against the UPS and tighten the captive screws. Do not overtighten.
3. If the Mains branch circuit breaker and load is off, turn the branch breaker on now.
4. Turn on the output circuit breaker on the rear of the UPS.
5. Turn on the input circuit breaker on the box.
6. Start the UPS according to the startup instructions.
7. Confirm that the UPS AVAILABLE lamp is lit beside the manual bypass switch.
8. Turn the manual bypass switch to the UPS position.
9. The UPS now protects the load.
!
!
all power to the load.
The Load is now unprotected from line disturbances or interruptions.
a. If needed, push the OFF button for one second once to transfer the load to bypass.
b. Press the OFF button twice within four seconds to turn the UPS off.
This input circuit breaker only cuts power to the connector between the box and UPS. The input
circuit breaker does not cut power to the manual bypass switch.
a. Loosen all three captive screws until box releases.
b. Pull box away from the UPS and set the box aside on a padded surface.
Press the ON button for one second.
CAUTION
Power is still passing through the box from mains to the load.
VORSICHT
Es fließt noch Netzstrom durch den Kasten zu den angeschlossenen
Geräten.
28