TLE8209-2SA Infineon Technologies, TLE8209-2SA Datasheet - Page 10

no-image

TLE8209-2SA

Manufacturer Part Number
TLE8209-2SA
Description
IC H-BRIDGE SPI PROG DSO-20
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE8209-2SA

Applications
DC Motor Driver
Number Of Outputs
1
Voltage - Load
4.5 V ~ 28 V
Voltage - Supply
4.4 V ~ 5.25 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (0.433", 11.0mm Width) Exposed Pad
Packages
PG-DSO-20
Current Limit (min.)
7.7 A
Rthjc (max)
1.6 K/W
Quiescent Current (max.)
20 µA
Operating Range
4.5 - 28 V
Rds (on) (typ./switch)
125.0 mOhm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE8209-2SA
Manufacturer:
INFINEON
Quantity:
1
Part Number:
TLE8209-2SA
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE8209-2SA
0
CONFIG0=’0’: ABE is inactive after VDD returned to normal operating voltage and filtering time has expired.
At the transition from overvoltage to normal condition, the output stages will return to normal operation. For output
control via SPI the bits MUX and SINx in the config register have to be re-programmed. New failures are not stored
to diagnostic registers during overvoltage, register content remains valid, writing new information to configure
registers is possible as far as they are not reset by ABE.
VDD Monitoring Test Mode
Testing of VDD monitoring is possible in SPI mode only. The latch function for over voltage at VDD has to be
switched of (CONFIG0=0 in STATCON_REG)
Testing upper threshold:
By writing 00xxxxxxb into STATCON_REG, the overvoltage threshold is reduced to VDD_TEST_H.
STATCON_REG bit 2 and 0 have to be LOW then. After writing 1xxxxxxxb to STATCON_REG, bit 2 and 0 in
STATCON_REG must be HIGH again
Testing lower threshold:
By writing 01xxxxxxb into STATCON_REG, the undervoltage threshold is increased to VDD_TEST_L.
STATCON_REG bit 2 and 1 have to be LOW then. After writing 1xxxxxxxb to STATCON_REG, bit 2 and 1 in
STATCON_REG must be HIGH again.
5.3
The voltage at
pin is also used to select SPI- or in status flag (SF) diagnostic mode. As soon as
device is put into status flag mode.
.
Figure 4
Data Sheet
(SF-mode / SPI-mode)
from internal logic
VDDIO - Digital Output Supply and Diagnostic Mode Selection
V
DDIO
V
to internal logic
DDIO
and SO-Pin
is used to supply the output buffer at the SO pin (serial output of SPI-interface). The VDDIO
+
-
10
SF/SPI - mode
threshold V
DDIO_L
V
DDIO
is lower than
Rev. 1.0, 2010-02-16
TLE8209-2SA
SO
VDDIO
Power Supply
V
DDIO_L
, the

Related parts for TLE8209-2SA