TLE8209-2SA Infineon Technologies, TLE8209-2SA Datasheet - Page 29

no-image

TLE8209-2SA

Manufacturer Part Number
TLE8209-2SA
Description
IC H-BRIDGE SPI PROG DSO-20
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE8209-2SA

Applications
DC Motor Driver
Number Of Outputs
1
Voltage - Load
4.5 V ~ 28 V
Voltage - Supply
4.4 V ~ 5.25 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (0.433", 11.0mm Width) Exposed Pad
Packages
PG-DSO-20
Current Limit (min.)
7.7 A
Rthjc (max)
1.6 K/W
Quiescent Current (max.)
20 µA
Operating Range
4.5 - 28 V
Rds (on) (typ./switch)
125.0 mOhm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE8209-2SA
Manufacturer:
INFINEON
Quantity:
1
Part Number:
TLE8209-2SA
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE8209-2SA
0
Table 8
ABE/DIS DIA21 DIA20 DIA11 DIA10 Description
Note:
The bit ABE/DIS shows directly the status of inputs ABE and DIS. It is set to ‘0’ if the power stages are disabled
by ABE or DIS.
The bits OT, CurrRed and CurrLim are latched. They will be reset with each read access. If the failure condition is
still present the according bits are set again.
Undervoltage at VS is reported and the outputs are switched off as long as the undervoltage condition is present.
The previous setting of the DIAx bits is masked but not reset. Once the supply voltage is back in the operating
range the diagnostic bits DIAxx will return to their setting before VS undervoltage. The outputs will return to normal
operation.
Detection of short circuit will switch of the output stages. In single half bridge operation only the affected output is
switched off. In H-Bridge mode both outputs are shut down. The outputs remain off until the failure condition is
removed and the diagnosis register is reset.
A short across the load may also be reported as SCG at one output and SCB at the other.
The diagnostic information DIAxx in the SPI interface is reset in the following cases:
Data Sheet
Read out of DIA_REG: only bit 4, 5 and 6 will be reset
Enabling or disabling of the bridge via ABE or DIS
Undervoltage at VDD
Reset command via SPI
X
X
1
1
1
1
1
1
1
1
0
0
0
Failure Encoding
X
X
X
1
0
1
1
0
1
0
1
1
1
X
X
X
1
1
0
1
1
0
0
1
1
1
X
X
X
X
1
0
1
1
1
0
0
0
0
X
X
X
X
1
1
0
1
0
1
0
0
0
no failure
short circuit to battery at OUT1 (SCB1)
short circuit to ground at OUT1 (SCG1)
no error detected at OUT1
short circuit to battery at OUT2 (SCB2)
short circuit to ground at OUT2 (SCG2)
no error detected at OUT2
short circuit accross load (HS1+LS2 active)
short circuit accross load (HS2+LS1 active)
Undervoltage at pin VS
open load (H-Bridge)
open load at OUT1 (single switch operation)
open load at OUT2 (single switch operation)
29
Rev. 1.0, 2010-02-16
TLE8209-2SA
SPI Interface
Comment
latched
latched
latched
latched
latched
latched
not latched
latched
latched
latched

Related parts for TLE8209-2SA