TLE8209-2SA Infineon Technologies, TLE8209-2SA Datasheet - Page 20

no-image

TLE8209-2SA

Manufacturer Part Number
TLE8209-2SA
Description
IC H-BRIDGE SPI PROG DSO-20
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE8209-2SA

Applications
DC Motor Driver
Number Of Outputs
1
Voltage - Load
4.5 V ~ 28 V
Voltage - Supply
4.4 V ~ 5.25 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (0.433", 11.0mm Width) Exposed Pad
Packages
PG-DSO-20
Current Limit (min.)
7.7 A
Rthjc (max)
1.6 K/W
Quiescent Current (max.)
20 µA
Operating Range
4.5 - 28 V
Rds (on) (typ./switch)
125.0 mOhm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE8209-2SA
Manufacturer:
INFINEON
Quantity:
1
Part Number:
TLE8209-2SA
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE8209-2SA
0
The short circuit to ground detection is activated when the current through one of the high side switches rises over
the threshold I
The output stage in which the short circuit was detected will be switched off within t
In H-bridge mode also the other output will be switched off after a short delay of t
In single switch mode only the affected output will be switched off.
8.5
A short circuit to battery is detected in the same way as a short circuit to ground, only in the low side switch instead
of the high side switch.
8.6
Short circuit over load is indicated by two failures - short circuit to ground on one output and short circuit to battery
on the other output. Both failure bits will be set in the SPI diagnostics register. Both output stages will be turned off.
8.7
In case of high DC-currents, insufficient cooling or high ambient temperature, the chip temperature may rise above
the thermal shut-down temperature
8.8
If the supply voltage at the VS pins falls below the undervoltage detection threshold V
are turned off. As soon as
8.9
Open load diagnosis is only possible if outputs are switched off by DIS or ABE. The diagnostic current sources are
deactivated in status flag mode. Diagnostic current sources are disconnected if outputs are active. That means
that the diagnostic current sources are also disconnected if the outputs are deactivated due to short circuit. The
open load detection in H-bridge mode is different from the open load detection in single switch mode.
Open Load Detection in H-Bridge mode
Figure 12
Data Sheet
V
ref_L
VDD
Short Circuit to Battery
Short Circuit across the Load
Overtemperature
Undervoltage Shut-Down
Open Load Diagnosis
Open Load Detection in H-Bridge Mode
OUK
and remains higher than I
+
-
V
S
rises above V
OUT1_L
T
SD
(see
OUT1
UV_ON
OUK
Figure
for at least the filter time t
again, the device is returning to normal operation.
OUT2
10). In that case, all output transistors are turned off.
20
DF_H
V
ref_L
within the blanking time t
DF_del
DF_OFF
Protection and Monitoring
UV_OFF
.
.
+
, the outputs switches
-
Rev. 1.0, 2010-02-16
TLE8209-2SA
OUT2_L
b
.