KSZ8842-PMBL Micrel Inc, KSZ8842-PMBL Datasheet - Page 81

2-Port Ethernet Switch/Repeater + 32-bit/33MHz PCI Bus Interface ( )

KSZ8842-PMBL

Manufacturer Part Number
KSZ8842-PMBL
Description
2-Port Ethernet Switch/Repeater + 32-bit/33MHz PCI Bus Interface ( )
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8842-PMBL

Controller Type
Ethernet Switch Controller
Interface
PCI
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LFBGA
Number Of Primary Switch Ports
2
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII
Power Supply Type
Analog/Digital
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.5V
Operating Supply Voltage (min)
3.1V
Operating Temperature Classification
Commercial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1636 - BOARD EVALUATION KSZ8842-PMQL
Current - Supply
-
Lead Free Status / RoHS Status
Supplier Unconfirmed, Lead free / RoHS Compliant
Other names
576-3089

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8842-PMBL
Manufacturer:
TI
Quantity:
1 164
Part Number:
KSZ8842-PMBL
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8842-PMBL
0
Part Number:
KSZ8842-PMBL AM
Manufacturer:
Micrel
Quantity:
1 053
Part Number:
KSZ8842-PMBL AM
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8842-PMBL AM TR
Manufacturer:
Micrel Inc
Quantity:
10 000
Micrel, Inc.
Port 1 PHY Special Control/Status, LinkMD (Offset 0x0510): P1SCSLMD
This register contains the port LinkMD control register for the switch port 1 function.
October 2007
14 – 13
8 – 0
Bit
Bit
15
12
11
10
9
Default
Default
0x000
0
0
0
0
1
0
R/W
R/W
RW
RW
RW
RW
RO
RO
RO
SC
Description
1011 = 48 Mbps
1100 = 64 Mbps
1101 = 72 Mbps
1110 = 80 Mbps
1111 = 88 Mbps
Note: For 10Base-T, rate settings above 10Mbps are set to the default
value 0000 (Not limited).
Note: When multiple queue select enable is off (only 1 queue per port),
rate limiting applies only to priority 0 queue.
Description
Vct 10M short
Less than 10 meter short
Vct result
[00] = normal condition
[01] = open condition has been detected in cable
[10] = short condition has been detected in cable
[11] = cable diagnostic test is failed
Vct enable
1 = the cable diagnostic test is enabled. It’ll be self-
cleared after VCT test is done
0 = it indicates the cable diagnostic test is
completed and the status information is valid for
read
Force Link
1 = Force link pass
0 = Normal Operation
Power Saving
1 = Disable
0 = Enable power saving
Remote loop back
1 = Loop back at PMD/PMA of port 1’s PHY
0 = normal operation.
VCT fault count
Distance to the fault. The distance is approximately
0.4mXvct_fault_count
81
Is the same as:
P1VCT, bit 12
P1VCT, bits 14-13
P1VCT, bit 15
P1PHYCTRL,
bit 3
P1PHYCTRL,
bit 2
P1PHYCTRL,
bit 1
P1VCT, bits 8-0
KSZ8842-PMQL/PMBL
M9999-100207-1.5