8845A/SU 120V Fluke Electronics, 8845A/SU 120V Datasheet - Page 75

PREC MLTMTR DMM BNCH 6.5 DIG RES

8845A/SU 120V

Manufacturer Part Number
8845A/SU 120V
Description
PREC MLTMTR DMM BNCH 6.5 DIG RES
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheets

Specifications of 8845A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
6.5
Display Type
VFD, Dual
Display Count
Varies
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Memory, RS-232
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2675292
614-1001
Measuring Frequency and Period
Measuring Resistance
The Meter measures the frequency, or period of ac signals between 3 Hz and 1 MHz,
applied between the Meter’s HI and LO connectors.
The G key not only activates the Meter’s Frequency/Period function, but also toggles
the Meter’s primary display between the signal’s frequency and period measurement.
Therefore, whether a frequency or period measurement appears after pressing G
depends on the condition this function was left in the last time it was used.
To make a frequency measurement:
1. Press G.
2. Connect the Meter to the signal as shown in Figure 4-1.
To make a period measurement:
1. Press G.
2. Connect the Meter to the signal as shown in Figure 4-1.
Function modifiers:
The Meter is capable of making two-wire and four-wire resistance measurements. Two-
wire measurements are easy to set up, and will make accurate measurements in most
applications. In a two-wire resistance measurement, both the source current and sensing
is done through the INPUT HI and LO terminals. A four-wire resistance measurement
Each press of G switches the measurement between frequency and
period.
If S is displayed, press G again to switch the primary display to frequency.
If HZ is displayed, press G again to switch the primary display to period.
APERTURE Displays three different gate time selections: 0.01, 0.1 and 1 second.
2ND MEAS Cycles the secondary display through the measurement functions
F1
These selections set the minimum amount of time the Meter takes to
measure frequency. Shorter gate times result in lower measurement
resolution.
listed below, and then off. When a second measurement function is
selected, the 2ND MEAS soft key label is highlighted.
Period – If a frequency measurement is in the primary display, the
period of the signal appears in the secondary display when the
2ND MEAS soft key is pressed.
0.000000
F2
Note
F3
F4
Hz
F5
Measuring Frequency and Period
Making Measurements
caw06f.eps
4-7