ZEN-10C2AR-A-V2 Omron, ZEN-10C2AR-A-V2 Datasheet - Page 163

100/240 VAC 6 IN, 4 OUT

ZEN-10C2AR-A-V2

Manufacturer Part Number
ZEN-10C2AR-A-V2
Description
100/240 VAC 6 IN, 4 OUT
Manufacturer
Omron
Series
ZEN V2r
Type
Expandabler

Specifications of ZEN-10C2AR-A-V2

Voltage - Supply
100 ~ 240VAC
Number Of I /o
6 Input, 4 Output
Display Type
LED
Output Type
Relay
Voltage Rating
100 V to 240 V
Input Type
AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Kit Contents
-
Analog Inputs
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Z2680
ZEN10C2ARAV2
Version Upgrades
Differences in Expansion I/O Units
Note
140
Type
Shape
Screw mounting method
Power supply
AC input
circuits
DC input
circuits
Contact current for Models
with Relay Outputs
Maximum voltage for Models
with Transistor Outputs
Connectable CPU Units
Refer to page 138 for details on compatible combinations of CPU Units and Expansion I/O
Units.
Item
Input impedance 680 k Ω
Isolation method Not isolated
Input common
Input voltage
ON voltage
Input impedance 6.5 k Ω
Isolation method ZEN-8E1DR: Not isolated
Input common
8 inputs/outputs
Width: 35 mm, no heat
dissipation slits
M3 (mounting holes on DIN
Track)
ZEN-8E1AR, -8E1DR:
Required.
ZEN-8E1DT: Not required.
Connected internally to power
supply terminal.
10.8 to 28.8 VDC
8 V
ZEN-8E1DT: Photocoupler
ZEN-8E1DR: Connected
internally to power supply
terminal.
ZEN-8E1DT: Separated as
COM terminal.
8 A/contact
The total for all outputs must be
as follows for each Unit: 20 A
28.8 VDC
V2 CPU Units (See note.)
ZEN-8E1@
4 inputs, 4 outputs, and
8 inputs/outputs
Width: 70 mm
M4 (holes on Expansion I/O
Units)
Not required.
83 k Ω
Photocoupler
Separated as COM terminal.
20.4 to 26.4 VDC
16 V
4.7 k Ω
Photocoupler
Separated as COM terminal.
8 A/contact
26.4 VDC
V1 and Pre-V1 CPU Units
ZEN-4E@ and ZEN-8E@
Appendix D

Related parts for ZEN-10C2AR-A-V2