Correcting Ladder Programs
3-5-3
Example: Deleting Serial Input M3
Example: Deleting Vertical Connecting Lines
3-5-4
72
• To insert a blank line, move the highlighted cursor to the beginning of the line where
• To add OR programming, inputs can be added between parallel inputs. Move the
the blank line is to be inserted and press the ALT Button.
highlighted cursor to the beginning of the line where the input is to be inserted.
Move the highlighted
cursor to the beginning
of the next line (the line
that will be after the
inserted line.)
Move the high-
lighted cursor to the
position of the input
to be deleted.
Move the highlighted
cursor to the beginning
of the next line (the line
that will be after the
inserted line.)
Deleting Inputs, Outputs, and Connection Lines
Inserting Lines
Blank line
Move the highlighted cursor to the position of
the input, output, or connection line to be
deleted and press the DEL Button.
Press the DEL Button to delete the input and
the related connecting lines at the same
time.
Move the highlighted cursor to the input
position to the right of the vertical line to be
deleted. Press the ALT Button to enable
drawing connection lines. The highlighted
cursor will change to a left arrow cursor.
Press the DEL Button to delete the vertical
connection line.
A circuit will be added here.
Press the ALT Button to insert one blank line.
An input will be added here.
Section 3-5