10070D AGILENT TECHNOLOGIES, 10070D Datasheet

no-image

10070D

Manufacturer Part Number
10070D
Description
OSCILLOSCOPE PROBE, 1:1, 20MHZ
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 10070D

Test Probe Type
Oscilloscope
Test Probe Functions
Frequency
For Use With
Infiniium 8000 Series Oscilloscopes
Lead Free Status / RoHS Status
na
Agilent Technologies
Infiniium 8000 Series Oscilloscopes
Superior mixed-signal analysis and debug
Data Sheet

10070D Summary of contents

Page 1

... Agilent Technologies Infiniium 8000 Series Oscilloscopes Superior mixed-signal analysis and debug Data Sheet ...

Page 2

If you haven’t purchased an Agilent scope lately, why should you consider one now? If you’re like most engineers, you never know what your next project will demand from you. You need an oscilloscope that can adapt to a wide ...

Page 3

What makes the Infiniium 8000 Series flexible enough for a whole range of test and debug challenges? Great measurement capability Oscilloscope: The powerful features of our Infi niium Series oscilloscopes, coupled with good scope specifi cations give you excellent signal ...

Page 4

Oscilloscope capabilities Scope channels ensure superior viewing of signals under test. All models incorporate a powerful, feature-packed Infi niium oscilloscope with responsive deep memory GHz bandwidth and 4 GSa/s high sample rates guarantee you’ll see a good ...

Page 5

MSO capabilities MSO models add 16 high-speed timing channels Use the timing channels to evaluate control signal relationships and data buses bits wide. Use symbols to more quickly interpret waveforms. Digital and mixed-signal trigger Trigger on and ...

Page 6

Infiniium Features DSO8064A/MSO8064A, DSO8104A/MSO8104A Serial, parallel and wideband signal decode Whether you are working on serial, parallel or wideband signals, you can use the 8000 Series to decode your waveforms. When you are working on parallel waveforms, you can even ...

Page 7

Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A Simple zooming Zooming with Infiniium’s graphical user interface is simple and convenient. Just use the mouse to draw a box around the area of interest and click inside. Zoom uses the full display so you ...

Page 8

Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A AutoMask and mask test Mask testing is simplified with AutoMask. Acquire a waveform, define tolerance limits, and create a test envelope. Mask testing provides a pass/fail comparison of an incoming signal to the test envelope. ...

Page 9

Connectivity and probing Connectivity Industry compatibility Export screen shots and waveforms in numerous industry-standard formats. In ad- dition, the 8000 Series supports compatibility with the following • IVI COM driver for application development environments such as Visual Studio, Agilent VEE, ...

Page 10

Up to 128 Mpts of MegaZoom fast deep memory sustains maximum sample rates for long time captures. Remote access via Web browser or programming environment with GPIB commands over LAN allows you to access your oscilloscope from any networked PC. ...

Page 11

MegaZoom technology enables you to quickly pan and zoom through the deepest waveforms for detailed analysis. USB 2.0 port directly on front panel makes it easy to save files to a USB mass storage device. AutoProbe interface completely configures your ...

Page 12

Agilent Infi niium portfolio Agilent’s Infi niium lineup includes 8000, 9000 and 90000A Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specifi c needs. ...

Page 13

Infiniium Advanced Application Software The Agilent 8000 Series Infiniium oscilloscope offers a broad portfolio of add-on applications that enables you to customize your oscilloscope. These applications are available as add-on options at your initial scope purchase or as user-installed options ...

Page 14

Infiniium Advanced Application Software Automotive serial data analysis software (Option 008 or N5402A) The N5402A automotive serial data analysis software allows engineers to view both protocol layer information and physical layer signal characteristics for CAN and FlexRay buses inside a ...

Page 15

Infiniium Advanced Application Software EZJIT jitter analysis software (Option 002 or E2681A) The E2681A jitter analysis option provides the most commonly needed jitter measurements, including cycle- cycle jitter, N-cycle jitter, period jitter, time interval error, setup and hold time, measurement ...

Page 16

Infiniium Advanced Application Software USB 2.0 performance validation and compliance software (N5416A) The Infiniium USB 2.0 electrical performance validation and compliance option provides a fast and reliable way to verify USB electrical specification compliance for USB 2.0 devices, hosts, and ...

Page 17

Infiniium Advanced Application Software Infiniium user-defined function (Option 010 or N5430A) The Agilent N5430A Infiniium user- defined function opens up new possibilities for mathematical analysis features of Infiniium by creating a gateway to MATLAB from MathWorks (www.mathworks.com/). You can now ...

Page 18

Infiniium Active Probing Probing importance If you are concerned about accurate reproduction of your signals as they appear on your device under test, you need the best end-to-end measurement system starting at the probe tip. To ensure that you achieve ...

Page 19

Infiniium Performance Characteristics Vertical: scope channels Input channels Analog bandwidth at 50 Ω (–3 dB)* 1 Calculated rise time at 50 Ω Input impedance* 2 Sensitivity Input coupling Hardware bandwidth limit 3 Vertical resolution Channel-to-channel isolation (any two channels with ...

Page 20

Infiniium Performance Characteristics Vertical: analog noise floor Volts/div Full bandwidth 100 mV 200 mV 500 MHz hardware 5 mV bandwidth limit 100 ...

Page 21

Infiniium Performance Characteristics Horizontal Main time base range Horizontal position range Delayed sweep range Resolution Time scale accuracy* Delta-time measurement accuracy* ≥ 256 averages, absolute (ps peak) ≥ 256 averages, standard deviation (ps rms) 1.2 No averaging, absolute (ps peak) ...

Page 22

Infiniium Performance Characteristics Acquisition: scope channels Real time sample rate (max) 2 channels Each channel Equivalent time sample rate (max) 5 Memory depth Standard Option 080 Option 160 Option 320 Option 640 Sampling modes Real time Normal Peak detect High ...

Page 23

Infiniium Performance Characteristics Trigger: scope channels Sensitivity 6 Internal Auxiliary Level range Internal Auxiliary Sweep modes Trigger coupling Trigger conditioning Trigger holdoff range Trigger jitter Trigger actions Trigger modes Edge Glitch Line Pattern State Delay by time Delay by events ...

Page 24

Infiniium Performance Characteristics Software trigger (InfiniiScan event identification software (Option 009)) Trigger modes Generic serial Measurements Non-monotonic Runt Zone qualify Trigger: digital channels Threshold range (user defined) Threshold accuracy* Predefined thresholds 24 (continued) Software triggers on NRZ-encoded data up to ...

Page 25

Infiniium Performance Characteristics Measurements and math Waveform measurements Voltage (scope channels only) Time (all channels) Time (scope channels only) Mixed (scope channels only) Frequency domain Eye pattern Jitter clock (scope only) Jitter data (scope only) Measurement modes Automatic measurements QuickMeas+ ...

Page 26

Infiniium Performance Characteristics Display Display Display Intensity grayscale: Resolution Annotation Grids Waveform styles Waveform update rate Real time mode (nominal) Computer system and peripherals, I/O ports Computer system and peripherals Operating system CPU PC system memory Drives Peripherals File types ...

Page 27

Infiniium Performance Characteristics General characteristics Temperature Operating Non-operating Humidity Operating Non-operating Altitude Operating Non-operating Vibration Operating Non-operating Power Weight Dimensions (excluding handle) Safety * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ...

Page 28

Infiniium Ordering Information 8000 Series oscilloscopes Bandwidth Input channels Maximum sample rate (2 channel) Standard memory (2 channel) The above models include: optical USB mouse, condensed keyboard, User’s Quick Start Guide in English language (other languages also available), accessory pouch, ...

Page 29

Infiniium Ordering Information Application options Options Description Digital analysis N5397A FPGA dynamic probe for Xilinx N5433A FPGA dynamic probe for Altera Serial data analysis Option 007 or N5391A Low-speed serial data analysis software for I Option 008 or N5402A Automotive ...

Page 30

Infiniium Ordering Information Other options Option Description Option 017 ≥ removable hard disk drive. Replaces ≥ internal hard disk with a ≥ (factory installed) removable hard disk. Order the N5422A for additional hard disk ...

Page 31

... N5416A USB 2.0 Electrical Performance Validation and Compliance Software U7233A DDR1 Compliance Test Application N5415A InfiniiScan Event Identification Software N5430A Infiniium User-Defined Function Application Software Multiple form factors from 20 MHz to >90 GHz 2 C and SPI Agilent Technologies Oscilloscopes | Industry leading specs Publication type Publication number Data sheet 5968-7141EN/ENUS ...

Page 32

... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2011 Printed in USA, January 14, 2011 5989-4271EN ...