ISP1506BBS,557 NXP Semiconductors, ISP1506BBS,557 Datasheet - Page 28
ISP1506BBS,557
Manufacturer Part Number
ISP1506BBS,557
Description
RF Transceiver USB2.0 ULPI DDR OTG
Manufacturer
NXP Semiconductors
Datasheet
1.ISP1506BBS557.pdf
(80 pages)
Specifications of ISP1506BBS,557
Operating Supply Voltage
1.65 V to 3.6 V
Mounting Style
SMD/SMT
Package / Case
HVQFN-24
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935278349557 ISP1506BBS
NXP Semiconductors
ISP1506A_ISP1506B_2
Product data sheet
Fig 9.
USE_EXT_VBUS_IND,
RXCMD A_VBUS_VLD indicator source
IND_PASSTHRU
9.5.2.3 Using and selecting the V
IND_COMPL
V
BUS
/FAULT
The V
link whenever there is a change in the V
must first enable the corresponding interrupts in the USB Interrupt Enable Rising Edge
and USB Interrupt Enable Falling Edge registers.
The link can use the V
shows the recommended usage for typical applications.
Table 14.
Standard USB host controllers:
500 mA on V
detect overcurrent conditions. If the external overcurrent detector provides a digital fault
signal, then the fault signal must be connected to the ISP1506 FAULT input pin, and the
link must do the following:
Standard USB peripheral controllers:
when V
start and end of USB peripheral operations. Detection of A_VBUS_VLD and SESS_END
thresholds is not needed for standard peripherals.
Application
Standard host
Standard peripheral no
OTG A-device
OTG B-device
1. Set the IND_COMPL bit in the Interface Control register to logic 0 or logic 1,
2. Set the USE_EXT_VBUS_IND bit in the OTG Control register to logic 1.
3. Set the IND_PASSTHRU bit in the Interface Control register to logic 1 (mandatory).
depending on the polarity of the external fault signal.
BUS
BUS
state encoding is shown in
V
A_VBUS_VLD comparator
is at a sufficient level for operation. SESS_VLD must be enabled to detect the
BUS
BUS
(V
indicators in RXCMD required for typical applications
BUS
in the range of 4.75 V to 5.25 V. An external circuit must be used to
< 4.4 V)
A_VBUS_VLD
yes
yes
no
Rev. 02 — 28 August 2008
BUS
internal A_VBUS_VLD
state to monitor V
BUS
state encoding
For standard hosts, the system must be able to provide
Table
BUS
Standard peripherals must be able to detect
SESS_VLD
no
yes
yes
yes
complement output
13. The ISP1506 will send an RXCMD to the
state. To receive V
BUS
ISP1506A; ISP1506B
and take appropriate action.
ULPI HS USB OTG transceiver
SESS_END
no
no
no
yes
(0, X)
(1, 1)
BUS
state updates, the link
© NXP B.V. 2008. All rights reserved.
RXCMD
A_VBUS_VLD
004aaa752
Table 14
27 of 79