UJA1061TW/3V0,518 NXP Semiconductors, UJA1061TW/3V0,518 Datasheet - Page 24

no-image

UJA1061TW/3V0,518

Manufacturer Part Number
UJA1061TW/3V0,518
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of UJA1061TW/3V0,518

Number Of Transceivers
1
Power Down Mode
Sleep/Standby
Operating Supply Voltage (min)
5.5V
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
UJA1061_6
Product data sheet
6.8.1.2 Off-line mode
6.8.2 LIN wake-up
6.8.3 Termination control
The LTC bit can be used to set the LIN transceiver to a Listen-only mode. The transmitter
output stage is disabled in this mode.
When leaving Active mode the LIN transmitter is disabled and the LIN receiver is
monitoring the LIN-bus for a valid wake-up.
Off-line mode is the low power mode of the LIN transceiver. The LIN transceiver is
disabled to save supply current. Pin RXDL reflects any wake-up event at the LIN-bus.
For a remote wake-up via LIN a LIN-bus signal is required as shown in
The RTLIN pin is in one of 3 different states: RTLIN = on, RTLIN = off or RTLIN = 75 μA;
see
During Active mode, with no short-circuit between the LIN-bus and GND, pin RTLIN
provides an internal switch to BAT42. For master and slave operation an external resistor,
1 kΩ or 30 kΩ respectively, can be applied between pins RTLIN and LIN. An external
diode in series with the termination resistor is not required due to the incorporated internal
diode.
Fig 10. LIN wake-up timing diagram
Figure
11.
All information provided in this document is subject to legal disclaimers.
wake-up
Rev. 06 — 9 March 2010
LIN
Fault-tolerant CAN/LIN fail-safe system basis chip
t BUS(LIN)
001aad447
UJA1061
© NXP B.V. 2010. All rights reserved.
Figure
10.
24 of 77