82P2282PF IDT, Integrated Device Technology Inc, 82P2282PF Datasheet - Page 293

82P2282PF

Manufacturer Part Number
82P2282PF
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82P2282PF

Screening Level
Industrial
Pin Count
100
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Not Compliant
E1 Overhead Interrupt Indication (061H, 161H)
TCRCEI:
TFEBEI:
ated.
FEBEI:
generated. During out of CRC Multi-Frame synchronization state, the Far End Block Error (FEBE) detection is suspended.
RAICRCI:
CFEBEI:
V52LINKI:
Programming Information
IDT82P2282
Bit Name
Default
Bit No.
Type
If the 4-bit Sa6 codeword of a CRC Sub Multi-Frame is matched with ‘0010’ or ‘0011’, the Network Terminal CRC Error event is generated.
= 0: No NT CRC Error event is detected.
= 1: The NT CRC Error event is detected.
This bit will be cleared if a ’1’ is written to it.
If the 4-bit Sa6 codeword of a CRC Sub Multi-Frame is matched with ‘0001’ or ‘0011’, the Network Terminal Far End Block Error event is gener-
= 0: No NT FEBE Error event is detected.
= 1: The NT FEBE Error event is detected.
This bit will be cleared if a ’1’ is written to it.
When CRC Multi-Frame is synchronized and any of the CRC error indication (E1 or E2) bits is received as a logic 0, a far end block error event is
= 0: No Far End Block Error (FEBE) event is detected.
= 1: The Far End Block Error (FEBE) event is detected.
This bit will be cleared if a ’1’ is written to it.
= 0: There is no status change on the RAICRCV bit (b, E1-04FH,...).
= 1: There is a transition (from ‘0’ to ‘1’ or from ‘1’ to ‘0’) on the RAICRCV bit (b2, E1-04FH,...).
This bit will be cleared if a ’1’ is written to it.
= 0: There is no status change on the CFEBEV bit (b, E1-04FH,...).
= 1: There is a transition (from ‘0’ to ‘1’ or from ‘1’ to ‘0’) on the CFEBEV bit (b, E1-04FH,...).
This bit will be cleared if a ’1’ is written to it.
= 0: There is no status change on the V52LINKV bit (b, E1-04FH,...).
= 1: There is a transition (from ‘0’ to ‘1’ or from ‘1’ to ‘0’) on the V52LINKV bit (b, E1-04FH,...).
This bit will be cleared if a ’1’ is written to it.
7
Reserved
6
TCRCEI
R
5
0
TFEBEI
R
4
0
293
DUAL T1/E1/J1 LONG HAUL / SHORT HAUL TRANSCEIVER
FEBEI
R
3
0
RAICRCI
R
2
0
CFEBEI
R
1
0
August 20, 2009
V52LINKI
R
0
0