ISP1301BS,151 NXP Semiconductors, ISP1301BS,151 Datasheet - Page 10

no-image

ISP1301BS,151

Manufacturer Part Number
ISP1301BS,151
Description
RF Transceiver USB OTG TRANSCEIVER
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1301BS,151

Number Of Transceivers
1
Esd Protection
YeskV
Operating Supply Voltage (typ)
Not RequiredV
Operating Temperature Classification
Industrial
Operating Supply Voltage (max)
Not RequiredV
Operating Supply Voltage (min)
Not RequiredV
Mounting
Surface Mount
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Operating Supply Voltage
1.65 V to 4.5 V
Lead Free Status / RoHS Status
Compliant
Other names
935273168151 ISP1301BS-S
Philips Semiconductors
ISP1301_3
Product data sheet
7.10.1 ADR/PSW
7.10 Detailed description of pins
7.9 Power-On Reset (POR)
When V
(t
The POR function can be explained by viewing dips at t2 to t3 and t4 to t5 on the V
curve
t0 — The internal POR starts with a LOW level.
t1 — The detector will see the passing of the trip level and a delay element will add
another t
t2-t3 — The internal POR pulse will be generated whenever V
more than 11 s.
t4-t5 — The dip is too short (< 11 s) and the internal POR pulse will not react and will
remain LOW.
The ADR/PSW pin has two functions. On reset (including power-on reset), the level on
this pin is latched as ADR_REG, which represents the Least Significant Bit (LSB) of the
I
ISP1301 is 010 1100 (2Ch); if bit ADR_REG = 1, the I
010 1101 (2Dh).
After reset, the ADR/PSW pin can be programmed as an output. If in the Mode Control 2
register bit PSW_OE = 1, then the ADR/PSW output will be enabled. The logic level will
be determined by bit ADR_REG. If bit ADR_REG = 0, then the ADR/PSW pin will be
driven HIGH. If bit ADR_REG = 1, then the ADR/PSW pin will be driven LOW.
The ADR/PSW pin can be used to turn on or off the external charge pump. The ISP1301
built-in charge pump supports V
support (for example, 50 mA), an external charge pump may be needed. In this case, the
ADR/PSW pin can act as a power switch for the external charge pump.
example of using external charge pump.
2
Fig 4. Internal POR timing
PORP
C-bus address of the ISP1301. If bit ADR_REG = 0, the I
) will be typically 200 ns. The pulse is started when V
(Figure
CC
(1) PORP = Power-On Reset Pulse
PORP
t0
is powered on, an internal POR is generated. The internal POR pulse width
4).
before it drops to LOW.
t1
t
PORP
Rev. 03 — 21 February 2006
BUS
current at 8 mA. If the application needs more current
t2
t3
t
PORP
2
C-bus address for the ISP1301 is
t4
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
2
CC
C-bus address for the
t5
CC
rises above V
drops below V
USB OTG transceiver
004aaa750
Figure 5
V
PORP
ISP1301
V
POR(trip)
CC
POR(trip)
(1)
POR(trip)
shows an
CC
.
9 of 51
for

Related parts for ISP1301BS,151