ISP1301BS,151 NXP Semiconductors, ISP1301BS,151 Datasheet - Page 31

no-image

ISP1301BS,151

Manufacturer Part Number
ISP1301BS,151
Description
RF Transceiver USB OTG TRANSCEIVER
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1301BS,151

Number Of Transceivers
1
Esd Protection
YeskV
Operating Supply Voltage (typ)
Not RequiredV
Operating Temperature Classification
Industrial
Operating Supply Voltage (max)
Not RequiredV
Operating Supply Voltage (min)
Not RequiredV
Mounting
Surface Mount
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Operating Supply Voltage
1.65 V to 4.5 V
Lead Free Status / RoHS Status
Compliant
Other names
935273168151 ISP1301BS-S
Philips Semiconductors
ISP1301_3
Product data sheet
12.4.2.1 Single read
12.4.2.2 Multiple read
12.4.2 Random address read
Figure 15
Table 39:
Figure 15
Table 40:
SDA line
S
Device select
ACK
Register address K
ACK
Device select
ACK
S
Read data K
No ACK
P
SDA line
S
Device select
ACK
Register address K
ACK
S
Device select
ACK
Read data K
ACK
Read data K + 1
ACK
:
Fig 14. Current address read
illustrates the byte sequence.
illustrates the byte sequence.
Transfer format description for single-byte read
Transfer format description for multiple-byte read
Description
master starts with a START condition
master transmits device address and writes command bit R/W = 0
slave generates an acknowledgment
master transmits (start) address of register K to be read from
slave generates an acknowledgment
master transmits device address and read command bit R/W = 1
slave generates an acknowledgment
master restarts with a START condition
slave transmits and master reads data from register K
master terminates the read operation by generating a No Acknowledge
master generates a STOP condition
Description
master starts with a START condition
master transmits device address and write command bit R/W = 0
slave generates an acknowledgment
master transmits (start) address of register K to be read from
slave generates an acknowledgment
master restarts with a START condition
master transmits device address and read command bit R/W = 1
slave generates an acknowledgment
slave transmits and master reads data from register K. After a byte is read,
the address is automatically incremented by 1.
master generates an acknowledgment
slave transmits and master reads data from register K + 1
master generates an acknowledgment
:
Rev. 03 — 21 February 2006
S
device select
current address read
rd
ACK
read data K
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
004aaa570
no ACK
P
USB OTG transceiver
ISP1301
30 of 51

Related parts for ISP1301BS,151