S71PL129JB0BAW9Z0 Spansion Inc., S71PL129JB0BAW9Z0 Datasheet - Page 139

no-image

S71PL129JB0BAW9Z0

Manufacturer Part Number
S71PL129JB0BAW9Z0
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of S71PL129JB0BAW9Z0

Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S71PL129JB0BAW9Z0
Manufacturer:
SPANSION
Quantity:
7 732
AC Characteristics
Notes:
1.
2. Address should not be changed within minimum t
3. The output load 50 pF with 50 ohm termination to V
4. The output load 5pF.
5. Applicable to A3 to A21 (32M and 64M) when CE1# is kept at Low.
6. Applicable only to A0, A1 and A2 (32M and 64M) when CE1# is kept at Low for the page address access.
7. In case Page Read Cycle is continued with keeping CE1# stays Low, CE1# must be brought to High within 4 µs. In other
8. Applicable when at least two of address inputs among applicable are switched from previous state.
9. t
10. If actual value of t
October 28, 2005 S71PL129Jxx_00_A8
Read Cycle Time
CE1# Access Time
OE# Access Time
Address Access Time
LB# / UB# Access Time
Page Address Access Time
Page Read Cycle Time
Output Data Hold Time
CE1# Low to Output Low-Z
OE# Low to Output Low-Z
LB# / UB# Low to Output Low-Z
CE1# High to Output High-Z
OE# High to Output High-Z
LB# / UB# High to Output High-Z
Address Setup Time to CE1# Low
Address Setup Time to OE# Low
Address Invalid Time
Address Hold Time from CE1# High
Address Hold Time from OE# High
WE# High to OE# Low Time for Read
CE1# High Pulse Width
Maximum value is applicable if CE#1 is kept at Low without change of address input of A3 to A21. If needed by system operation, please
contact local Spansion representative for the relaxation of 1µs limitation.
words, Page Read Cycle must be closed within 4 µs.
amount of subtracting the actual value from the specified minimum value.
RC
(min) and t
(Under Recommended Operating Conditions Unless Otherwise
Noted)
Read Operation
Parameter
PRC
(min) must be satisfied.
WHOL
is shorter than specified minimum values, the actual t
A d v a n c e
Symbol
t
t
t
t
t
t
t
t
t
WHOL
S71PL129JC0/S71PL129JB0/S71PL129JA0
t
t
t
t
CHAH
OHAH
t
t
t
t
t
t
OHZ
t
t
PAA
PRC
CLZ
OLZ
CHZ
BHZ
ASC
ASO
BLZ
OH
RC
CE
OE
AA
BA
AX
CP
I n f o r m a t i o n
RC
Min.
70
−6
10
10
10
.
-6
-6
DD
5
5
0
0
x 0.5 (16M), The output load 50 pF (32M and 64M).
16M
N/A
N/A
1000
1000
Max.
60
40
60
30
20
20
20
10
Min.
65
20
–6
10
–6
–6
25
12
5
5
0
0
32M
AA
1000
1000
1000
Max.
14.5
of following Read can become longer by the
65
40
65
30
20
20
20
10
Min.
65
20
–6
10
–6
–6
25
12
5
5
0
0
64M
1000
1000
1000
Max.
65
40
65
30
20
20
14
20
10
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
1, 6, 7
137
Notes
1, 2
3, 5
5, 8
3,6
10
3
3
3
3
4
4
4
3
3
3
9

Related parts for S71PL129JB0BAW9Z0