FDC37B782-NS Standard Microsystems (SMSC), FDC37B782-NS Datasheet - Page 101

no-image

FDC37B782-NS

Manufacturer Part Number
FDC37B782-NS
Description
Manufacturer
Standard Microsystems (SMSC)
Datasheet

Specifications of FDC37B782-NS

Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37B782-NS
Manufacturer:
MOT
Quantity:
11
Part Number:
FDC37B782-NS
Manufacturer:
Microchip Technology
Quantity:
10 000
BIT 5 DIRECTION
If mode=000 or mode=010, this bit has no effect
and the direction is always out regardless of the
state of this bit. In all other modes, Direction is
valid and a logic 0 means that the printer port is in
output mode (write); a logic 1 means that the
printer port is in input mode (read).
BITS 6 and 7 during a read are a low level, and
cannot be written.
cFifo (Parallel Port Data FIFO)
ADDRESS OFFSET = 400h
Mode = 010
Bytes written or DMAed from the system to this
FIFO are transmitted by a hardware handshake to
the peripheral using the standard parallel port
protocol. Transfers to the FIFO are byte aligned.
This mode is only defined for the forward direction.
ecpDFifo (ECP Data FIFO)
ADDRESS OFFSET = 400H
Mode = 011
Bytes written or DMAed from the system to this
FIFO, when the direction bit is 0, are transmitted
by a hardware handshake to the peripheral using
the ECP parallel port protocol. Transfers to the
FIFO are byte aligned.
Data bytes from the peripheral are read under
automatic hardware handshake from ECP into this
FIFO when the direction bit is 1. Reads or DMAs
from the FIFO will return bytes of ECP data to the
system.
tFifo (Test FIFO Mode)
ADDRESS OFFSET = 400H
Mode = 110
Data bytes may be read, written or DMAed to or
from the system to this FIFO in any direction.
Data in the tFIFO will not be transmitted to the to
the parallel port lines using a hardware protocol
handshake. However, data in the tFIFO may be
displayed on the parallel port data lines.
The tFIFO will not stall when overwritten or
underrun. If an attempt is made to write data to a
full tFIFO, the new data is not accepted into the
101
tFIFO. If an attempt is made to read data from an
empty tFIFO, the last data byte is re-read again.
The full and empty bits must always keep track of
the correct FIFO state. The tFIFO will transfer data
at the maximum ISA rate so that software may
generate performance metrics.
The FIFO size and interrupt threshold can be
determined by writing bytes to the FIFO and
checking the full and serviceIntr bits.
The writeIntrThreshold can be determined by
starting with a full tFIFO, setting the direction bit to
0 and emptying it a byte at a time until serviceIntr
is set. This may generate a spurious interrupt, but
will indicate that the threshold has been reached.
The readIntrThreshold can be determined by
setting the direction bit to 1 and filling the empty
tFIFO a byte at a time until serviceIntr is set. This
may generate a spurious interrupt, but will indicate
that the threshold has been reached.
Data bytes are always read from the head of tFIFO
regardless of the value of the direction bit. For
example if 44h, 33h, 22h is written to the FIFO,
then reading the tFIFO will return 44h, 33h, 22h in
the same order as was written.
cnfgA (Configuration Register A)
ADDRESS OFFSET = 400H
Mode = 111
This register is a read only register. When read,
10H is returned. This indicates to the system that
this is an 8-bit implementation. (PWord = 1 byte)
cnfgB (Configuration Register B)
ADDRESS OFFSET = 401H
Mode = 111
BIT 7 compress
This bit is read only. During a read it is a low level.
This means that this chip does not support
hardware RLE compression.
hardware de-compression!
BIT 6 intrValue
Returns the value on the ISA IRq line to determine
possible conflicts.
BITS [5:3] Parallel Port IRQ (read-only)
Refer to Table 44B.
It does support

Related parts for FDC37B782-NS