A80960HD80S L2GK Intel, A80960HD80S L2GK Datasheet - Page 41

A80960HD80S L2GK

Manufacturer Part Number
A80960HD80S L2GK
Description
Manufacturer
Intel
Datasheet

Specifications of A80960HD80S L2GK

Family Name
i960
Device Core Size
32b
Frequency (max)
80MHz
Instruction Set Architecture
RISC
Supply Voltage 1 (typ)
3.3V
Operating Supply Voltage (max)
3.45V
Operating Supply Voltage (min)
3.15V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Through Hole
Pin Count
168
Package Type
CPGA
Lead Free Status / RoHS Status
Compliant
Datasheet
Table 22. 80960Hx D.C. Characteristics (Sheet 2 of 2)
I
Current on
the VCC5
Pin
C
C
C
R
NOTES:
10.Pin capacitance is characterized, but not tested.
CC5
1. I
2. I
3. Output Capacitance is the capacitive load of a floating output.
4. Measured with device operating and outputs loaded to the test conditions in
5. I
6. I
7. I
8. Worst case is V
9. I
Symbol
IN
OUT
I/O
PU
Per the conditions described in
outputs loaded to the test conditions described in
page
one of the worst case instruction mixes with V
V
or ONCE mode with V
CC
CC
CC
CC
CC
CC5
CC
Maximum is measured at worst case frequency, V
Typical is not tested.
Active (Power Supply) value is provided for selecting your system’s power supply. It is measured using
Active (Thermal) value is provided for your system’s thermal management. Typical I
Test (Power modes) refers to the I
= 3.3 V and temperature = 25°C. This parameter is characterized but not tested.
is tested at V
45. Input signals rise to V
Input Capacitance for:
Output Capacitance of each
output pin
I/O Pin Capacitance
Internal Pull-Up Resistance
for ONCE, TMS, TDI and
TRST
CC
CC
Parameter
= 3.45 V, 0 °C.
= 3.0 V, VCC5 = 5.25 V.
CC
= 3.45 V.
80960HD
80960HA
80960HT
Section 4.3, “Recommended Connections” on page
CC
PGA
PQ4
and fall to V
CC
values that are tested when the 80960HA/HD/HT is in Reset mode
Min
30
CC
SS
.
= 3.45 V. This parameter is characterized but not tested.
Section 4.7.1, “AC Test Conditions” on page
CC
Typ
65
, and temperature, with device operating and
Max
200
200
200
100
12
12
12
12
Figure 8, “AC Test Load” on
Units
µA
k
pF
pF
pF
pF
38.
9
F
F
F
80960HA/HD/HT
C
C
C
CC
= 1 MHz
= 1 MHz
= 1 MHz
is measured with
Notes
45.
10
3,
10
10
41

Related parts for A80960HD80S L2GK