Table 2: LAN100 Registers
PNX17XX_SER_1
Preliminary data sheet
Bit
4
3
2
1
0
Offset 0x07 2208
The bits in this register are write-only; writing resets the corresponding bits in the RxFilterWoLStatus register.
31:9
8
7
6
5
4
3
2
1
0
Offset 0x07 220C
See
operation code fields.
31:24
23:20
19:16
15:12
11:8
7:4
3:0
Offset 0x07 2210
Section 3.3 on page 23-25
Symbol
AcceptMulticastHashWo
L
AcceptUnicastHashWoL RO
AcceptMulticastWoL
AcceptBroadcastWoL
AcceptUnicastWoL
-
MagicPacketWoLClr
RxFilterWoLClr
PatternMatchWoLClr
AcceptPerfectWoLClr
AcceptMulticastHashWo
LClr
AcceptUnicastHashWoL
Clr
AcceptMulticastWoLClr
AcceptBroadcastWoLClr WO
AcceptUnicastWoLClr
-
Join0123
Join123
Join012
Join23
Join12
Join01
Receive Filter WoL Clear Register (RxFilterWoLClear)
Pattern Matching Join Register (PatternMatchJoin)
Hash filter table LSBs register (HashFilterL)
…Continued
for a description of the functions of this register. See
Acces
s
RO
RO
RO
RO
-
WO
WO
WO
WO
WO
WO
WO
WO
-
R/W
R/W
R/W
R/W
R/W
R/W
Value
Rev. 1 — 17 March 2006
Description
When set to ‘1’, a multicast packet that passed the imperfect hash
filter caused WoL.
When set to ‘1’, a unicast packet that passed the imperfect hash
filter caused WoL.
When set to ‘1’, a multicast packet caused WoL.
When set to ‘1’, a broadcast packet caused WoL.
When set to ‘1’, a unicast packet caused WoL.
Unused
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
When set, the corresponding status bit in the RxFilterWoLStatus
register is cleared.
Unused
Control bits for joining the result of Join012 and Join123.
Control bits for joining the result of Join12 and Join23.
Control bits for joining the result of Join01 and Join12.
Control bits for joining the result of pattern-matching filter units 2
and 3.
Control bits for joining the result of pattern-matching filter units 1
and 2.
Control bits for joining the result of pattern-matching filter units 0
and 1.