E5@Z
Parameters
Some parameters are not displayed depending on the
model of the Controller and parameter settings. For details,
refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital
Temperature Controllers User's Manual (Cat. No. H207).
C
C
C
C
C
C
C
P
P
P
P
P
Adjustment Level
cmwt
lcr1
sp-0
sp-1
sp-2
sp-3
insh
insl
ct1
hb1
hs1
ins
50.0
off
off
at
M
M
M
M
M
M
M
M
M
M
M
M
M
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
AT execute/cancel
Communications writing
Heater current 1 value
monitor
Leakage current 1
monitor
Heater burnout detection 1
HS alarm 1
SP 0
SP1
SP 2
SP 3
Temperature input shift
Upper-limit temperature
input shift value
Lower-limit temperature
input shift value
SP used by
multi-SP
1-point shift
2-point shift
Press the O Key less than 1 s.
Press the O Key less than 1 s.
Set either of these parameters.
C
P
P
P
C
P
C
C
C
P
P
c-sc
c-db
of-r
chys
sprt
ol-h
ol-l
hys
105.0
1.00
233
50.0
-5.0
off
M
M
M
M
M
M
M
M
M
M
M
8.0
0.0
1.0
1.0
40
p
i
d
Proportional band
Integral time
Derivative time
Cooling coefficient
Dead band
Manual reset value
Clear the offset during sta-
bilization of P or PD control.
Hysteresis (heating)
Hysteresis (cooling)
SP ramp set value
MV upper limit
MV lower limit
Heating/cool-
ing
PID settings
Hysteresis
settings
Press the
O Key for
at least 3 s.
Starting in manual mode.
Press the O and M Keys for at
least 3 s. Display flashes.
The time taken to move to the protect level can be
adjusted by changing the "Move to protect level
time" setting.
PV/MV
C
P
P
P
Manual control level
oapt
icpt
wtpt
25
C
C
P
P
C
P
P
P
M
M
off
M
m-sp
sp-m
lcr1
PID control
only
0
1
a-m
ct1
r-s
Protect Level
run
25
M
25
M
M
M
M
M
M
M
Operation/adjustment protect
Restricts displaying and
modifying menus in operation,
adjustment, and manual
control levels.
Initial setting/communications
protect
This protect level restricts
movement to the initial setting,
communications setting, and
advanced function setting levels.
Setting change protect
Protects changes to setups by
operating the front panel keys.
0.0
0.0
0
0
0
Process value
Added when Additional
PV display is ON.
Process value/
set point
Auto/manual switch
PID control only.
Added when auto/manual
select addition is ON.
Multi-SP
set point setting
Set point during SP
ramp
Heater current 1 value
monitor
Leakage current 1
monitor
RUN/STOP
Power ON
Press the
O Key for
at least 1 s
Operation Level
Press the O and
for at least 1 s.
Starting in automatic
mode.
Displayed only for models with communications.
Changes are effective after cycling power or
after a software reset.
Communications Setting Level
C
C
C
C
C
C
C
C
C
P
P
al-1
al1h
al1l
al-2
al2h
al2l
al-3
al3h
al3l
psel
u-no
sbit
prty
sdwt
c-o
bps
len
even
M
M
M
M
M
M
M
M
cwf
M
M
M
M
M
M
M
M
M
M
Press the O Key for at
least 3 s. Displays other than
that for switching between
automatic and manual.
0.0
0.0
9.6
M
20
o
0
0
0
0
0
0
0
0
0
1
7
2
Keys
Alarm value 1
Alarm value
upper limit 1
Alarm value
lower limit 1
Alarm value 2
Alarm value
upper limit 2
Alarm value
lower limit 2
Alarm value 3
Alarm value
upper limit 3
Alarm value
lower limit 3
MV monitor
(heating)
MV monitor
(cooling)
Protocol setting
Switches between CompoWay/F
(SYSWAY) and Modbus.
Communications Unit No.
Communications baud rate
Communications
data length
Communications stop bits
Communications parity
Send data wait time
CompoWay/F
(SYSWAY) only
Press the O Key
less than 1 s