ENC624J600-I/PT Microchip Technology, ENC624J600-I/PT Datasheet - Page 97

IC ETHERNET CTRLR W/SPI 64-TQFP

ENC624J600-I/PT

Manufacturer Part Number
ENC624J600-I/PT
Description
IC ETHERNET CTRLR W/SPI 64-TQFP
Manufacturer
Microchip Technology
Datasheets

Specifications of ENC624J600-I/PT

Package / Case
64-TFQFP
Controller Type
Ethernet Controller
Interface
SPI
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
96mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Input Voltage Range (max)
5.5 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3 V to 3.6 V
Supply Current (max)
117 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
AC164132 - BOARD DAUGHTER PICTAIL ETHERNET
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ENC624J600-I/PT
Manufacturer:
Microchip
Quantity:
3 200
Part Number:
ENC624J600-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Company:
Part Number:
ENC624J600-I/PT
Quantity:
4 900
Company:
Part Number:
ENC624J600-I/PT
Quantity:
12 888
10.0
To minimize the number of frames that the host controller
must process, ENC424J600/624J600 devices incorpo-
rate 11 different receive filters to discard unwanted
frames. The following filters are available:
• CRC Error Collection Filter
• Runt Error Collection Filter
• CRC Error Rejection Filter
• Runt Error Rejection Filter
• Unicast Collection Filter
• Not-Me Unicast Collection Filter
• Multicast Collection Filter
• Broadcast Collection Filter
• Hash Table Collection Filter
• Magic Packet™ Collection Filter
• Pattern Match Collection Filter
Each filter is software configurable, and can be individu-
ally enabled or disabled, using the ERXFCON register
(Register 10-1). Each filter is either a Collection or a
Rejection filter, with incoming frames passing sequen-
tially through each enabled filter. The first filter to make a
definitive decision for a frame takes priority over all
others. Collection filters either force a frame to be
accepted or defer the decision to a lower priority filter.
Similarly, Rejection filters either discard frames or defer
to lower priority filters. Frames that pass through all filters
without specifically being accepted are discarded.
Figure 10-1 demonstrates this decision tree.
 2010 Microchip Technology Inc.
RECEIVE FILTERS
ENC424J600/624J600
At power-up, the CRC Error Rejection, Runt Error
Rejection, Unicast Collection and Broadcast Collection
filters are enabled, and all others are disabled. With
these settings, the device will only accept Broadcast
frames and frames specifically addressed to the local
MAC address. Invalid frames and those destined for
other nodes will be automatically rejected.
Note 1: The MAC internally processes and filters
2: If the Ethernet Receive Enable bit, RXEN
Ethernet control frames as they arrive
and before they reach these filters. For
the application to receive Ethernet control
frames, enable the PASSALL option
(MACCON1<1> = 1 ).
(ECON1<0>), is set, the filters may make
an incorrect decision if any of the receive
filters are reconfigured at the exact
moment a new frame is being received.
To avoid this behavior, clear the RXEN bit
prior to changing any receive filter
settings.
DS39935C-page 95

Related parts for ENC624J600-I/PT