RP-LS42F-75LE BANNER ENGINEERING, RP-LS42F-75LE Datasheet - Page 2

no-image

RP-LS42F-75LE

Manufacturer Part Number
RP-LS42F-75LE
Description
SAFETY SWITCH; ROPE PULL; LATCH; 2 NC; MAX 75M; E-STOP BUTTON
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-LS42F-75LE

Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Rope Pull Emergency Stop Switches –
2
In the United States, the functions that Banner rope pull emergency stop switches are intended to perform are regulated by the Occupational
Safety and Health Administration (OSHA). Whether or not any particular rope pull switch installation meets all applicable OSHA requirements
depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the switches are applied,
installed, wired, operated, and maintained.
Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This information is
found in the instruction manual packaged with each rope pull switch. Direct any questions regarding the use or installation of rope pull switches to
the factory applications department at the telephone numbers or address shown below.
Banner Engineering Corp. recommends that rope pull emergency stop switches be applied according to the guidelines set forth in standards listed
below. In addition, the user of Banner rope pull switches has the responsibility to ensure that all local, state, and national laws, rules, codes,
and regulations relating to the use of Banner rope pull switches in any particular application are satisfied. Extreme care is urged that all legal
requirements have been met and that all installations and maintenance instructions are followed.
U. S. Standards Applicable to Use of Emergency Stop Safety Modules
European Standards Applicable to Use of Emergency Stop Safety Modules
ANSI B11
NFPA79
ANSI/RIA R15.06
ISO/TR12100-1&-2
(EN 292-1 & -2)
ISO13849-1 (EN 954-1)
IEC/EN 60204-1
ISO13850 (EN 418)
IEC 60947-5-5
P/N 67709 rev. A
Important Information
Regarding the Use of Rope Pull Emergency Stop Switches
Standards for Machine Tools “Safety Requirements for the Construction, Care and Use”
Available from:
“Electrical Standard for Industrial Machinery (1997)”
Available from:
“Safety Requirements for Industrial Robots and Robot Systems”
Available from:
“Safety of Machinery—Basic Concepts, General Principles for Design
Part 1: Basic Terminology, Methodology”; Part 2: Technical Principles and Specifications
“Safety of Machines—Safety Related Parts of Control Systems”
“Electrical Equipment of Machines: Part 1: General Requirements”
Also, request a type “C” standard for your specific machinery.
“Safety of Machinery—Emergency Stop Equipment Functional Aspects, Principles for Design”
“Electrical Emergency Stop Devices with Mechanical Latching Function”
Available from:
Toll Free:
Email:
Address:
Safety Director
AMT—The Association for Manufacturing Technology
7901 Westpark Drive
McLean, VA 22102
Tel.: 703-893-2900
National Fire Protection Association
1 Batterymarch Park, P.O. Box 9101
Quincy, MA 02269-9101
Tel.: 800-344-3555
Robotic Industries Association
900 Victors Way, P.O. Box 3724
Ann Arbor, MI 48106
Tel.: 734-994-6088
Global Engineering Documents
15 Inverness Way East
Englewood, CO 80112-5704
Tel.: 800-854-7179
Application Assistance
1-888-3-SENSOR (1-888-373-6767)
sensors@bannerengineering.com
9714 Tenth Avenue North
Minneapolis, MN 55441
RP-LS42F-75L.. Series
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164

Related parts for RP-LS42F-75LE