RP-LS42F-75LE BANNER ENGINEERING, RP-LS42F-75LE Datasheet - Page 7

no-image

RP-LS42F-75LE

Manufacturer Part Number
RP-LS42F-75LE
Description
SAFETY SWITCH; ROPE PULL; LATCH; 2 NC; MAX 75M; E-STOP BUTTON
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-LS42F-75LE

Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Figure 7. Resetting the latch
Model RP-LS42F-75L
and RP-LS42F-75LF
Model RP-LS42F-75LE
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
NOTE: Proper rope tension must
be displayed before latch
can be reset
Pull
Rope Pull Emergency Stop Switches –
Turn clockwise
to reset
E-Stop and Latch Reset
Following the pulling of the rope or the pressing of the E-stop button (model RP-LS42F-
75LE), the latch must be reset. The procedure differs slightly between the two models.
See Figure 6.
Models RP-LS42F-75L and RP-LS42F-75LF: Pull the blue reset button; the arrows
should then be centered in the tensioning indicator window.
Model RP-LS42F-75LE: The E-stop can be reset only when proper tension is indicated.
Turn the yellow knob clockwise until the blue arrow is in the “I” position (indicating that
the latch has been reset). The latch should make an audible click when reset.
Each rope pull emergency stop installation should be tested for proper machine
shutdown response at each shift change or machine setup by a Designated Person*.
In addition, a Qualified Person* should check for proper rope tension, and adjust as
needed, on a periodic schedule determined by the user, based upon severity of the
operating environment and the frequency of switch actuations.
The pulleys and other moving parts associated with the rope should be periodically
lubricated. If inspection reveals dirt on the rope pull switch or rope assembly, the dirt
must be cleaned off and its cause must be eliminated. Replace the rope pull switch
and/or rope assembly when any parts (including contacts) or assemblies are found to be
damaged, broken, deformed, or badly worn.
The rope pull switch and rope assembly should be replaced at specified intervals based
upon the environment and operating conditions. Replacement of the rope pull switch and
rope assembly should be considered after no more than 500,000 operations. Always
test the control system for proper functioning under machine control conditions after
maintenance or replacement of the rope pull switch.
* A Designated Person is identified in writing by the employer as being appropriately trained to perform
Banner rope pull emergency stop switches have no field-replaceable components.
Contact the Banner Factory Application Engineering Group at the address or the
numbers listed at the bottom of the back page. They will issue an RMA (Return
Merchandise Authorization) number for your paperwork, and give you the proper shipping
address.
a specified checkout procedure. A Qualified Person possesses a recognized degree or certificate
or has extensive knowledge, training, and experience to be able to solve problems relating to the
emergency stop rope pull switch installation.
E-Stop Reset
Maintenance
Repairs
RP-LS42F-75L.. Series
P/N 67709 rev. A
7