RP-LS42F-75LE BANNER ENGINEERING, RP-LS42F-75LE Datasheet - Page 5

no-image

RP-LS42F-75LE

Manufacturer Part Number
RP-LS42F-75LE
Description
SAFETY SWITCH; ROPE PULL; LATCH; 2 NC; MAX 75M; E-STOP BUTTON
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-LS42F-75LE

Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Figure 4. Applying tension to the rope
Figure . Assembly of rope and hardware (rope span components are listed on page 10)
8 mm wrench
NOTE:
All hardware is supplied by the user. The
switch mounting holes are on a mounting
pattern of 0 x 124 millimeters, and
accept M5 (#10) hardware.
Banner Engineering Corp. • Minneapolis, MN U.S.A.
Tension
indicator
Too Little
Tension
Shown
www.bannerengineering.com • Tel: 763.544.3164
(models RP-LS42F-75LE and
RP-LS42F-75LF)
Rope Pull Emergency Stop Switches –
Proper
Tension
Shown
Tension
indicator
L3
for actuation of switch
Installing Model RP-LS42F-75LE or RP-LS42F-75LF
These models have their own internal turnbuckle and clamp to tension the rope and
to hold it in place. This innovative design provides for quick and easy rope fixing and
tensioning, and means no external turnbuckle is required, nor is any additional clamp
required at the switch end of the rope.
To install the rope at the switch end, strip away several inches of the cable covering, as
shown in Figure 2. Loosen the set screw on the switch fitting, using a 4 mm hex wrench.
Insert the cable into the center hole, and pull the cut end out from the side hole. When
the tension is correct, tighten the set screw to hold the rope firmly in place.
Tensioning the Rope
After the rope span components are installed, apply tension to the rope until the arrows
in the tensioning indicator are centered on the line in the indicator window (see Figure 4).
This indicates sufficient rope tension. (Contacts 21/22 and 41/42 will close.)
Model RP-LS42F-75L: Turn the turnbuckle until the arrows are centered.
Models RP-LS42F-75LE
and RP-LS42F-75LF: Turn the shaft of the switch using an 8 mm wrench as shown in
Pull hard on the rope and reset the latch several times. If the arrows in the tensioning
indicator window do not return to the correct position (centered on the line in the
window), further tighten or loosen the rope tension as needed until proper tension is
shown after such a reset.
400 mm (16") max.
**Distance must allow necessary clearance to all mounting hardware
*Closer, if possible
75 m (245')
Max. Total
Length
L1
L1
L4
L4
Note:
Force to actuate must
not exceed 200 N (45lbf)
3-5 m (10'-15')
Between Pulleys
Max. Distance
Figure 4, until the arrows are centered.
L2
L1
L2
L2
Spring/Turnbuckle
150 mm (6")
Max. Distance To
L4
L*
RP-LS42F-75L.. Series
150 mm (6")
Fitting to Pulley
Min. Distance
Spring breakage
protector cable
L4**
L3
340 mm
P/N 67709 rev. A