WM8311GEB/V Wolfson Microelectronics, WM8311GEB/V Datasheet - Page 185

no-image

WM8311GEB/V

Manufacturer Part Number
WM8311GEB/V
Description
POWER MANAGEMENT SUBSYSTEM, 121BGA
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8311GEB/V

Supply Voltage
5.5V
No. Of Step-down Dc - Dc Converters
4
No. Of Ldo Regulators
7
Digital Ic Case Style
BGA
No. Of Pins
121
No. Of Regulated Outputs
9
Operating Temperature Range
-40°C To
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Pre-Production
REGISTER
R16398
(400Eh) ON
Source
w
ADDRESS
BIT
15
11
10
9
8
7
6
5
4
3
2
1
ON_RTC_ALM
RESET_CNV_
ON_WDOG_T
ON_SW_REQ
ON_PEN_DO
ON_ON_PIN
RESET_SW
RESET_HW
ON_TRANS
ON_SYSLO
ON_GPIO
ON_CHG
LABEL
WN
UV
O
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
Most recent ON/WAKE event type
0 = WAKE transition
1 = ON transition
Reset by state machine.
Most recent ON/WAKE event type
0 = Not caused by GPIO input
1 = Caused by GPIO input
Reset by state machine.
Most recent WAKE event type
0 = Not caused by SYSVDD
1 = Caused by SYSLO threshold. Note that the SYSLO
threshold cannot trigger an ON event.
Reset by state machine.
Most recent WAKE event type
0 = Not caused by Pen Down
1 = Caused by Touch Panel Pen Down detection.
Note that the Pen Down detection cannot trigger an ON
event.
Reset by state machine.
Most recent WAKE event type
0 = Not caused by Battery Charger
1 = Caused by Battery Charger
TBC if this could cause ON due to Charger plugged in?
Reset by state machine.
Most recent WAKE event type
0 = Not caused by Watchdog timer
1 = Caused by Watchdog timer
Reset by state machine.
Most recent WAKE event type
0 = Not caused by software WAKE
1 = Caused by software WAKE command (CHIP_SLP
= 0)
Reset by state machine.
Most recent ON/WAKE event type
0 = Not caused by RTC Alarm
1 = Caused by RTC Alarm
Reset by state machine.
Most recent ON/WAKE event type
0 = Not caused by the ON pin
1 = Caused by the ON pin
Reset by state machine.
Most recent ON event type
0 = Not caused by undervoltage
1 = Caused by a Device Reset due to a Converter
(LDO or DC-DC) undervoltage condition
Reset by state machine.
Most recent ON event type
0 = Not caused by Software Reset
1 = Caused by Software Reset
Reset by state machine.
Most recent ON event type
0 = Not caused by Hardware Reset
1 = Caused by Hardware Reset
Reset by state machine.
DESCRIPTION
PP, December 2009, Rev 3.0
REFER TO
WM8311
185