FLUKE-190-204/AM/S Fluke Electronics, FLUKE-190-204/AM/S Datasheet - Page 123

no-image

FLUKE-190-204/AM/S

Manufacturer Part Number
FLUKE-190-204/AM/S
Description
SCOPEMETER 4CH 200MHZ COLOR SCC
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-204/AM/S

Bandwidth
200MHz
Channels
4
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Green, 1 Red, 1 Gray)
Sampling Rate (per Second)
1.25GS/s
Input Impedance
1M
Rise Time (typ)
1.7nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB Cable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1175
AC+DC Voltage (True RMS)
Maximum Voltage
Maximum Resolution
Full Scale Reading........................................ 1100 counts
Accuracy
Amperes (AMP)
With Optional Current Probe or Current Shunt
Ranges ............................ same as VDC, VAC, VAC+DC
Probe Sensitivity ................. 100 µV/A, 1 mV/A, 10 mV/A,
All accuracies are valid if:
with 10:1 probe................................................... 1000 V
direct (1:1)............................................................ 300 V
with 10:1 probe...................................................... 1 mV
direct (1:1).......................................................... 100 µV
DC to 60 Hz ................................. ±(1.5 % + 10 counts)
60 Hz to 20 kHz............................ ±(2.5 % + 15 counts)
20 kHz to 1 MHz.............................. ±(5 % + 20 counts)
1 MHz to 25 MHz .......................... ±(10 % + 20 counts)
For higher frequencies the instrument’s frequency roll off
starts affecting accuracy.
The waveform amplitude is larger than one division
At least 1.5 waveform period is on the screen
100 mV/A, 400 mV/A, 1 V/A, 10 V/A, and 100 V/A
Accuracy .......................... same as VDC, VAC, VAC+DC
Peak
Modes ................... Max peak, Min peak, or peak-to-peak
Maximum Voltage
Maximum Resolution
Full Scale Reading ..........................................800 counts
Accuracy
Frequency (Hz)
Range...................................... 1.000 Hz to full bandwidth
Full Scale Reading ..........................................999 counts
Accuracy
with 10:1 probe ...................................................1000 V
direct (1:1) ............................................................300 V
with 10:1 probe ....................................................10 mV
direct (1:1) .............................................................1 mV
Max peak or Min peak ............................... ±0.2 division
Peak-to-peak ............................................. ±0.4 division
1 Hz to full bandwidth ...................... ±(0.5 % +2 counts)
(5 s/div to 10 ns/div and 10 periods on the screen).
(add current probe or current shunt accuracy)
Automatic Scope Measurements
115