C8051F700-GQR Silicon Laboratories Inc, C8051F700-GQR Datasheet - Page 284

no-image

C8051F700-GQR

Manufacturer Part Number
C8051F700-GQR
Description
MCU 8-Bit C8051F70x 8051 CISC 15KB Flash 1.8V/3V 64-Pin TQFP T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051F700-GQR

Package
64TQFP
Device Core
8051
Family Name
C8051F70x
Maximum Speed
25 MHz
Ram Size
512 Byte
Program Memory Size
15 KB
Operating Supply Voltage
1.8|3 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
54
Interface Type
I2C/SMBus/SPI/UART
On-chip Adc
16-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F700-GQR
Manufacturer:
APTINA
Quantity:
1 001
Part Number:
C8051F700-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051F70x/71x
34. Programmable Counter Array
The Programmable Counter Array (PCA0) provides enhanced timer functionality while requiring less CPU
intervention than the standard 8051 counter/timers. The PCA consists of a dedicated 16-bit counter/timer
and three 16-bit capture/compare modules. Each capture/compare module has its own associated I/O line
(CEXn) which is routed through the Crossbar to Port I/O when enabled. The counter/timer is driven by a
programmable timebase that can select between seven sources: system clock, system clock divided by
four, system clock divided by twelve, the external oscillator clock source divided by 8, Timer 0 overflows, or
an external clock signal on the ECI input pin. Each capture/compare module may be configured to operate
independently in one of six modes: Edge-Triggered Capture, Software Timer, High-Speed Output, Fre-
quency Output, 8 to 11-Bit PWM, or 16-Bit PWM (each mode is described in Section
“34.3. Capture/Compare Modules” on page 286). The external oscillator clock option is ideal for real-time
clock (RTC) functionality, allowing the PCA to be clocked by a precision external oscillator while the inter-
nal oscillator drives the system clock. The PCA is configured and controlled through the system controller's
Special Function Registers. The PCA block diagram is shown in Figure 34.1
284
Capture/Compare
Figure 34.1. PCA Block Diagram
Module 0
SYSCLK/12
SYSCLK/4
Timer 0 Overflow
SYSCLK
External Clock/8
ECI
Crossbar
Port I/O
Rev. 1.0
Capture/Compare
Module 1
CLOCK
MUX
PCA
16-Bit Counter/Timer
Capture/Compare
Module 2

Related parts for C8051F700-GQR