C8051F700-GQR Silicon Laboratories Inc, C8051F700-GQR Datasheet - Page 99

no-image

C8051F700-GQR

Manufacturer Part Number
C8051F700-GQR
Description
MCU 8-Bit C8051F70x 8051 CISC 15KB Flash 1.8V/3V 64-Pin TQFP T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051F700-GQR

Package
64TQFP
Device Core
8051
Family Name
C8051F70x
Maximum Speed
25 MHz
Ram Size
512 Byte
Program Memory Size
15 KB
Operating Supply Voltage
1.8|3 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
54
Interface Type
I2C/SMBus/SPI/UART
On-chip Adc
16-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F700-GQR
Manufacturer:
APTINA
Quantity:
1 001
Part Number:
C8051F700-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
With the CIP-51's maximum system clock at 25 MHz, it has a peak throughput of 25 MIPS. The CIP-51 has
a total of 109 instructions. The table below shows the total number of instructions that require each execu-
tion time.
16.1. Instruction Set
The instruction set of the CIP-51 System Controller is fully compatible with the standard MCS-51™ instruc-
tion set. Standard 8051 development tools can be used to develop software for the CIP-51. All CIP-51
instructions are the binary and functional equivalent of their MCS-51™ counterparts, including opcodes,
addressing modes and effect on PSW flags. However, instruction timing is different than that of the stan-
dard 8051.
16.1.1. Instruction and CPU Timing
In many 8051 implementations, a distinction is made between machine cycles and clock cycles, with
machine cycles varying from 2 to 12 clock cycles in length. However, the CIP-51 implementation is based
solely on clock cycle timing. All instruction timings are specified in terms of clock cycles.
Due to the pipelined architecture of the CIP-51, most instructions execute in the same number of clock
cycles as there are program bytes in the instruction. Conditional branch instructions take one less clock
cycle to complete when the branch is not taken as opposed to when the branch is taken. Table 16.1 is the
CIP-51 Instruction Set Summary, which includes the mnemonic, number of bytes, and number of clock
cycles for each instruction.
Clocks to Execute
Number of Instructions
26
1
50
2
2/3
Rev. 1.0
5
14
3
3/4
7
C8051F70x/71x
4
3
4/5
1
5
2
8
1
99