IDT82P2816BB IDT, Integrated Device Technology Inc, IDT82P2816BB Datasheet - Page 93

no-image

IDT82P2816BB

Manufacturer Part Number
IDT82P2816BB
Description
IC LIU T1/J1/E1 16+1CH 416-PBGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82P2816BB

Function
Line Interface Unit (LIU)
Interface
E1, J1, T1
Number Of Circuits
1
Voltage - Supply
1.8V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
*
Includes
Defect and Alarm Detection, Driver Over-Current Detection and Protection, LLOS Detection, PRBSARB / IB Detection and Generation
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Supply
-
Power (watts)
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82P2816BB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2816BB
Manufacturer:
ADI
Quantity:
6 358
Part Number:
IDT82P2816BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2816BBG
Manufacturer:
IDT Integrated Device Technolo
Quantity:
135
Part Number:
IDT82P2816BBG
Manufacturer:
IDT
Quantity:
70
Part Number:
IDT82P2816BBG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
ERR - Error Detection & Insertion Control Register
Address: 00EH, 04EH, 08EH, 0CEH, 10EH, 14EH, 18EH, 1CEH, (CH1~CH8)
Type: Read / Write
Default Value: 00H
Programming Information
IDT82P2816
4 - 2
1 - 0
Bit
EXZ_DEF
7
6
5
1
0
20EH, 24EH, 28EH, 2CEH, 30EH, 34EH, 38EH, 3CEH, (CH9~CH16)
7CEH (CH0)
7
CNT_SEL[2:0] These bits select what kind of error to be counted by the internal Error Counter.
CNT_STOP
TDLOS[1:0]
EXZ_DEF
ERR_INS
BPV_INS
CNT_MD
Name
BPV_INS
6
This bit selects the EXZ definition standard.
0: ANSI. (default)
1: FCC.
This bit controls whether to insert a bipolar violation (BPV) to the transmit path.
Writing ‘1’ to this bit will insert a BPV on the next available mark in the data stream to be transmitted.
This bit is cleared once the BPV insertion is completed.
This bit controls whether to insert a single bit error to the generated PRBS/ARB pattern.
A transition from ‘0’ to ‘1’ on this bit will insert a single bit error to the generated PRBS/ARB pattern.
This bit is cleared once the single bit error insertion is completed.
000: Disable. (default)
001: LBPV.
010: LEXZ.
011: LBPV + LEXZ.
100: SBPV.
101: SEXZ.
110: SBPV + SEXZ.
111: PRBS/ARB error.
This bit determines whether the ERRCH & ERRCL registers are updated automatically or manually.
0: Manually by setting the CNT_STOP bit (b0, ERR,...). (default)
1: Every-one second automatically.
This bit is valid only when the CNT_MD bit (b1, ERR,...) is ‘0’.
A transition from ‘0’ to ‘1’ on this bit updates the ERRCH & ERRCL registers.
This bit must be cleared before the next round.
These bits select the period. When the amplitude of the data is less than a certain voltage for the period, TLOS is declared. The
voltage is determined by the TALOS bits (b3~2, LOS,...).
00: 16-pulse.
01: 32-pulse. (default)
1X: 64-pulse.
ERR_INS
5
CNT_SEL2
4
16(+1) CHANNEL HIGH-DENSITY T1/E1/J1 LINE INTERFACE UNIT
93
CNT_SEL1
3
Description
CNT_SEL0
2
CNT_MD
1
February 6, 2009
CNT_STOP
0

Related parts for IDT82P2816BB