AT32UC3L0256 Atmel Corporation, AT32UC3L0256 Datasheet - Page 70

no-image

AT32UC3L0256

Manufacturer Part Number
AT32UC3L0256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT32UC3L0256

Flash (kbytes)
256 Kbytes
Pin Count
48
Max. Operating Frequency
50 MHz
Cpu
32-bit AVR
# Of Touch Channels
17
Hardware Qtouch Acquisition
Yes
Max I/o Pins
36
Ext Interrupts
36
Usb Speed
No
Usb Interface
No
Spi
5
Twi (i2c)
2
Uart
4
Lin
4
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
460
Analog Comparators
8
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.62 to 3.6
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
35
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3L0256-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3L0256-D3HR
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT32UC3L0256-H
Manufacturer:
ATMEL
Quantity:
270
Part Number:
AT32UC3L0256-H
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
8.3.1.5
8.3.1.6
8.3.1.7
70
AVR32
Bus Error Exception on Data Access
Bus Error Exception on Instruction Fetch
NMI Exception
The Bus Error on Data Access exception is generated when the data bus detects an error condi-
tion. This exception is caused by events unrelated to the instruction stream, or by data written to
the cache write-buffers many cycles ago. Therefore, execution can not be resumed in a safe
way after this exception. The value placed in RAR_EX is unrelated to the operation that caused
the exception. The exception handler is responsible for performing the appropriate action.
The Bus Error on Instruction Fetch exception is generated when the data bus detects an error
condition. This exception is caused by events related to the instruction stream. Therefore, exe-
cution can be restarted in a safe way after this exception, assuming that the condition that
caused the bus error is dealt with.
The NMI exception is generated when the NMI input line to the core is asserted. The NMI excep-
tion can not be masked by the SR[GM] bit. However, the core ignores the NMI input line when
processing an NMI Exception (the SR[M2:M0] bits are B’111). This guarantees serial execution
of NMI Exceptions, and simplifies the NMI hardware and software mechanisms.
Since the NMI exception is unrelated to the instruction stream, the instructions in the pipeline are
allowed to complete. After finishing the NMI exception routine, execution should continue at the
instruction following the last completed instruction in the instruction stream.
*(--SP
*(--SP
SR[R] = 0;
SR[J] = 0;
SR[M2:M0] = B’110;
SR[EM] = 1;
SR[GM] = 1;
PC = EVBA + 0x08;
*(--SP
*(--SP
SR[R] = 0;
SR[J] = 0;
SR[M2:M0] = B’110;
SR[EM] = 1;
SR[GM] = 1;
PC = EVBA + 0x0C;
*(--SP
*(--SP
SR[R] = 0;
SR[J] = 0;
SR[M2:M0] = B’111;
SR[EM] = 1;
SR[GM] = 1;
PC = EVBA + 0x10;
SYS
SYS
SYS
SYS
SYS
SYS
) = PC of first non-issued instruction;
) = SR;
) = PC of first non-issued instruction;
) = SR;
) = PC of first noncompleted instruction;
) = SR;
32000D–04/2011