SAM3N4B Atmel Corporation, SAM3N4B Datasheet - Page 486

no-image

SAM3N4B

Manufacturer Part Number
SAM3N4B
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3N4B

Flash (kbytes)
256 Kbytes
Pin Count
64
Max. Operating Frequency
48 MHz
Cpu
Cortex-M3
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Quadrature Decoder Channels
2
Usb Speed
No
Usb Interface
No
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
10
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
24
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
28.10.5.3
Figure 28-27. Master Performs a General Call
486
486
GCACC
SVACC
TXD
SAM3N
SAM3N
General Call
S
GENERAL CALL
GENERAL CALL
0000000 + W
The general call is performed in order to change the address of the slave.
If a GENERAL CALL is detected, GACC is set.
After the detection of General Call, it is up to the programmer to decode the commands which
come afterwards.
In case of a WRITE command, the programmer has to decode the programming sequence and
program a new SADR if the programming sequence matches.
Figure 28-27 on page 486
Note:
This method allows the user to create an own programming sequence by choosing the program-
ming bytes and the number of them. The programming sequence has to be provided to the
master.
WRITE command = 00000100X
A
RESET command = 00000110X
Reset or write DADD
Reset after read
describes the General Call access.
A
DATA1
Programming sequence
New SADR
A
DATA2
A
New SADR
11011A–ATARM–04-Oct-10
11011A–ATARM–04-Oct-10
A
P

Related parts for SAM3N4B