ADUC834 Analog Devices, ADUC834 Datasheet - Page 18

no-image

ADUC834

Manufacturer Part Number
ADUC834
Description
Precision Analog Microcontroller: 1MIPS 8052 MCU + 62kB Flash + 16/24-Bit ADC + 12-Bit DAC
Manufacturer
Analog Devices
Datasheet

Specifications of ADUC834

Mcu Core
8052
Mcu Speed (mips)
1
Sram (bytes)
2304Bytes
Gpio Pins
34
Adc # Channels
4
Other
PWM

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUC834
Manufacturer:
ADI
Quantity:
4 000
Part Number:
ADUC834BS
Manufacturer:
TKS
Quantity:
15 200
Part Number:
ADUC834BS
Manufacturer:
ADI
Quantity:
455
Part Number:
ADUC834BS
Manufacturer:
AD
Quantity:
20 000
Part Number:
ADUC834BSZ
Manufacturer:
TOSHIBA
Quantity:
1 200
Part Number:
ADUC834BSZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADUC834BSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuC834
ADCMODE (ADC Mode Register)
Used to control the operational mode of both ADCs.
SFR Address
Power-On Default Value
Bit Addressable
Bit
7
6
5
4
3
2
1
0
NOTES
1. Any change to the MD bits will immediately reset both ADCs. A write to the MD2–0 Bits with no change is also treated as a reset. (See exception to this in Note 3 below.)
2. If ADC0CON is written when ADC0EN = 1, or if ADC0EN is changed from 0 to 1, then both ADCs are also immediately reset. In other words, the primary ADC
3. On the other hand, if ADC1CON is written or if ADC1EN is changed from 0 to 1, only the auxiliary ADC is reset. For example, if the primary ADC is continuously
4. Once ADCMODE has been written with a calibration mode, the RDY0/1 bits (ADCSTAT) are immediately reset and the calibration commences. On completion,
5. Any calibration request of the auxiliary ADC while the temperature sensor is selected will fail to complete. Although the RDY1 bit will be set at the end of the
6. Calibrations are performed at maximum SF (see SF SFR) value guaranteeing optimum calibration operation.
is given priority over the auxiliary ADC and any change requested on the primary ADC is immediately responded to.
converting when the auxiliary ADC change or enable occurs, the primary ADC continues undisturbed. Rather than allow the auxiliary ADC to operate with a phase
difference from the primary ADC, the auxiliary ADC will fall into step with the outputs of the primary ADC. The result is that the first conversion time for the
auxiliary ADC will be delayed up to three outputs while the auxiliary ADC update rate is synchronized to the primary ADC.
the appropriate calibration registers are written, the relevant bits in ADCSTAT are written, and the MD2–0 bits are reset to 000 to indicate the ADC is back in
power-down mode.
calibration cycle, no update of the calibration SFRs will take place and the ERR1 bit will be set.
Name
–––
–––
ADC0EN
ADC1EN
–––
MD2
MD1
MD0
Description
Reserved for Future Use
Reserved for Future Use
Primary ADC Enable.
Set by the user to enable the primary ADC and place it in the mode selected in MD2–MD0 below.
Cleared by the user to place the primary ADC in power-down mode.
Auxiliary ADC Enable.
Set by the user to enable the auxiliary ADC and place it in the mode selected in MD2–MD0 below.
Cleared by the user to place the auxiliary ADC in power-down mode.
Reserved for Future Use
Primary and auxiliary ADC Mode bits.
These bits select the operational mode of the enabled ADC as follows:
MD2 MD1 MD0
0
0
0
0
1
1
1
1
D1H
00H
No
0
0
1
1
0
0
1
1
Table V. ADCMODE SFR Bit Designations
0
1
0
1
0
1
0
1
ADC Power-Down Mode (Power-On Default)
Idle Mode. In Idle Mode, the ADC filter and modulator are held in a reset state
although the modulator clocks are still provided.
Single Conversion Mode. In Single Conversion Mode, a single conversion is
performed on the enabled ADC. On completion of the conversion, the ADC data
registers (ADC0H/M/L and/or ADC1H/L) are updated, the relevant flags in the
ADCSTAT SFR are written, and power-down is re-entered with the MD2–MD0
accordingly being written to 000.
Continuous Conversion. In Continuous Conversion Mode, the ADC data registers
are regularly updated at the selected update rate (see SF Register).
Internal Zero-Scale Calibration. Internal short automatically connected to the
enabled ADC input(s).
Internal Full-Scale Calibration Internal or External V
XREF0 and XREF1 bits in ADC0/1CON) is automatically connected to the
enabled ADC input(s) for this calibration.
System Zero-Scale Calibration. User should connect system zero-scale input to
the enabled ADC input(s) as selected by CH1/CH0 and ACH1/ACH0 bits in
the ADC0/1CON Register.
System Full-Scale Calibration. User should connect system full-scale input to
the enabled ADC input(s) as selected by CH1/CH0 and ACH1/ACH0 bits in the
ADC0/1CON Register.
–18–
REF
(as determined by
REV. A

Related parts for ADUC834