STM8S007C8 STMicroelectronics, STM8S007C8 Datasheet - Page 42

no-image

STM8S007C8

Manufacturer Part Number
STM8S007C8
Description
Value line, 24 MHz STM8S 8-bit MCU, 64 Kbytes Flash, true data EEPROM
Manufacturer
STMicroelectronics
Datasheet

Specifications of STM8S007C8

Max Fcpu
up to 24 MHz, 0 wait states @ fCPU≤ 16 MHz
Program
64 Kbytes Flash; data retention 20 years at 55 °C after 100 cycles
Data
128 bytes true data EEPROM; endurance 100 kcycles
Ram
6 Kbytes
Advanced Control Timer
16-bit, 4 CAPCOM channels, 3 complementary outputs, dead-time insertion and flexible synchronization

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STM8S007C8T6
Manufacturer:
ST
Quantity:
14 000
Part Number:
STM8S007C8T6
Manufacturer:
ST
Quantity:
500
Part Number:
STM8S007C8T6
Manufacturer:
ST
Quantity:
500
Part Number:
STM8S007C8T6
Manufacturer:
ST
Quantity:
500
Part Number:
STM8S007C8T6
Manufacturer:
ST
0
Part Number:
STM8S007C8T6
Manufacturer:
ST
Quantity:
200
Part Number:
STM8S007C8T6
Manufacturer:
ST
Quantity:
20 000
Part Number:
STM8S007C8T6
0
Part Number:
STM8S007C8T6X
Manufacturer:
ST
Quantity:
248
Electrical characteristics
9
9.1
9.1.1
9.1.2
9.1.3
9.1.4
42/90
Electrical characteristics
Parameter conditions
Unless otherwise specified, all voltages are referred to V
Minimum and maximum values
Unless otherwise specified the minimum and maximum values are guaranteed in the worst
conditions of ambient temperature, supply voltage and frequencies by tests in production on
100 % of the devices with an ambient temperature at T
the selected temperature range).
Data based on characterization results, design simulation and/or technology characteristics
are indicated in the table footnotes and are not tested in production. Based on
characterization, the minimum and maximum values refer to sample tests and represent the
mean value plus or minus three times the standard deviation (mean ± 3 Σ).
Typical values
Unless otherwise specified, typical data are based on T
only as design guidelines and are not tested.
Typical ADC accuracy values are determined by characterization of a batch of samples from
a standard diffusion lot over the full temperature range, where 95% of the devices have an
error less than or equal to the value indicated (mean ± 2 Σ)
Typical curves
Unless otherwise specified, all typical curves are given only as design guidelines and are
not tested.
Typical current consumption
For typical current consumption measurements, V
together in the configuration shown in
Figure 5.
Supply current measurement conditions
5 V or 3.3 V
Doc ID 022171 Rev 2
A
Figure
5.
DD
V
V
V
V
V
V
DD
DDA
DDIO
SS
SSA
SSIO
, V
A
A
DDIO
SS
= 25 °C and T
= 25 °C, V
.
.
and V
DDA
DD
= 5 V. They are given
A
are connected
= T
Amax
STM8S007C8
(given by