MAS281 Dynex, MAS281 Datasheet - Page 36

no-image

MAS281

Manufacturer Part Number
MAS281
Description
MIL-STD-1750A Microprocessor
Manufacturer
Dynex
Datasheet
MAS281
NOTES:
36/55
1. The "don't care" state will continue to exist until HLDAK = HIGH, RDY will then resume normal operation.
2. HOLD falling may occur at any time during software execution. The diagram shows the last possible time it can occur
and be assured of entering the HOLD state after the current instruction completes execution.
3. Other required input states: RESET = LOW.
Figure 22: Hold State Generation Timing