MX29LV040 Macronix, MX29LV040 Datasheet - Page 4

no-image

MX29LV040

Manufacturer Part Number
MX29LV040
Description
4M-Bit CMOS Single Voltage 3V Flash Memory
Manufacturer
Macronix
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MX29LV040CQC-70G
Manufacturer:
MXIC
Quantity:
1 831
Part Number:
MX29LV040CQC-70G.
Manufacturer:
MXIC
Quantity:
1 437
Part Number:
MX29LV040CQI-55G
Manufacturer:
MXIC
Quantity:
6 000
Part Number:
MX29LV040CQI-70G
Manufacturer:
MXIC
Quantity:
5 530
Part Number:
MX29LV040CQI-70G
Manufacturer:
Macronix
Quantity:
10 000
Part Number:
MX29LV040CQI-70G
Manufacturer:
MXIC/旺宏
Quantity:
20 000
Part Number:
MX29LV040CQI-70G
Quantity:
378
Part Number:
MX29LV040CQI-90G
Manufacturer:
MXIC
Quantity:
5 530
Part Number:
MX29LV040CT2I-70G
Manufacturer:
MXIC/旺宏
Quantity:
20 000
Part Number:
MX29LV040CTC-70
Manufacturer:
MXIC/旺宏
Quantity:
20 000
Part Number:
MX29LV040CTI-70G
Manufacturer:
MXIC/旺宏
Quantity:
20 000
Part Number:
MX29LV040CTI-90
Manufacturer:
MXIC
Quantity:
1 000
Part Number:
MX29LV040QI-70
Manufacturer:
MX
Quantity:
20 000
Part Number:
MX29LV040TC-12
Manufacturer:
MXIC
Quantity:
1 000
AUTOMATIC PROGRAMMING
The MX29LV040 is byte programmable using the Auto-
matic Programming algorithm. The Automatic Program-
ming algorithm makes the external system do not need
to have time out sequence nor to verify the data pro-
grammed. The typical chip programming time at room
temperature of the MX29LV040 is less than 10 seconds.
AUTOMATIC CHIP ERASE
The entire chip is bulk erased using 10 ms erase pulses
according to MXIC's Automatic Chip Erase algorithm.
Typical erasure at room temperature is accomplished in
less than 4 second. The Automatic Erase algorithm au-
tomatically programs the entire array prior to electrical
erase. The timing and verification of electrical erase are
controlled internally within the device.
AUTOMATIC SECTOR ERASE
The MX29LV040 is sector(s) erasable using MXIC's Auto
Sector Erase algorithm. The Automatic Sector Erase
algorithm automatically programs the specified sector(s)
prior to electrical erase. The timing and verification of
electrical erase are controlled internally within the de-
vice. An erase operation can erase one sector, multiple
sectors, or the entire device.
AUTOMATIC PROGRAMMING ALGORITHM
MXIC's Automatic Programming algorithm requires the
user to only write program set-up commands (including
2 unlock write cycle and A0H) and a program command
(program data and address). The device automatically
times the programming pulse width, provides the pro-
gram verification, and counts the number of sequences.
A status bit similar to Data# Polling and a status bit
toggling between consecutive read cycles, provide feed-
back to the user as to the status of the programming
operation. Refer to write operation status table 6, for more
information on these status bits.
AUTOMATIC ERASE ALGORITHM
MXIC's Automatic Erase algorithm requires the user to
write commands to the command register using stan-
P/N:PM0722
4
dard microprocessor write timings. The device will auto-
matically pre-program and verify the entire array. Then
the device automatically times the erase pulse width,
provides the erase verification, and counts the number
of sequences. A status bit toggling between consecu-
tive read cycles provides feedback to the user as to the
status of the erasing operation.
Register contents serve as inputs to an internal state-
machine which controls the erase and programming cir-
cuitry. During write cycles, the command register inter-
nally latches address and data needed for the program-
ming and erase operations. During a system write cycle,
addresses are latched on the falling edge, and data are
latched on the rising edge of WE# or CE#, whichever
happens first.
MXIC's Flash technology combines years of EPROM
experience to produce the highest levels of quality, reli-
ability, and cost effectiveness. The MX29LV040 electri-
cally erases all bits simultaneously using Fowler-
Nordheim tunneling. The bytes are programmed by us-
ing the EPROM programming mechanism of hot elec-
tron injection.
During a program cycle, the state-machine will control
the program sequences and command register will not
respond to any command set. During a Sector Erase
cycle, the command register will only respond to Erase
Suspend command. After Erase Suspend is completed,
the device stays in read mode. After the state machine
has completed its task, it will allow the command regis-
ter to respond to its full command set.
AUTOMATIC SELECT
The automatic select mode provides manufacturer and
device identification, and sector protection verification,
through identifier codes output on Q7~Q0. This mode is
mainly adapted for programming equipment on the de-
vice to be programmed with its programming algorithm.
When programming by high voltage method, automatic
select mode requires VID (11.5V to 12.5V) on address
pin A9 and other address pin A6, A1, and A0 as referring
to Table 2. In addition, to access the automatic select
codes in-system, the host can issue the automatic se-
lect command through the command register without
requiring VID, as shown in table 3.
To verify whether or not sector being protected, the sec-
MX29LV040
REV. 1.3, DEC. 20, 2004

Related parts for MX29LV040