s-24cs64a Seiko Instruments Inc., s-24cs64a Datasheet - Page 21

no-image

s-24cs64a

Manufacturer Part Number
s-24cs64a
Description
2-wire Cmos Serial E2prom
Manufacturer
Seiko Instruments Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-24CS64A
Manufacturer:
SIEKO
Quantity:
1 000
Part Number:
s-24cs64a01-H8T1
Manufacturer:
SEIKO
Quantity:
4 016
Part Number:
s-24cs64a01-J8T1G
Manufacturer:
SAMSUNG
Quantity:
1 783
Part Number:
s-24cs64a0I-J8T1G
Manufacturer:
SEKIO
Quantity:
20 000
Company:
Part Number:
s-24cs64a0I-J8T1G
Quantity:
1 941
Part Number:
s-24cs64aOI-J8T1GE
Manufacturer:
SEIKO
Quantity:
20 000
Part Number:
s-24cs64aOI-J8V1G
Manufacturer:
SEIKO
Quantity:
1 000
Part Number:
s-24cs64aOI-T8T1GE
Manufacturer:
SEIKO
Quantity:
20 000
Rev.4.1
3. Matching phases while E
The S-24CS64A does not have a pin for resetting (the internal circuit), therefore, the E
forcibly reset externally. If a communication interruption occurs in the E
software.
For example, even if a reset signal is input to the microprocessor, the internal circuit of the E
reset as long as the stop condition is not input to the E
same status and cannot shift to the next operation. This symptom applies to the case when only the
microprocessor is reset when the power supply voltage drops. With this status, if the power supply voltage
is restored, reset the E
The following shows this reset method.
[How to reset E
The E
is outputting the acknowledge signal, 0 is output to the SDA line. In this status, the microprocessor
cannot output an instruction to the SDA line. In this case, terminate the acknowledge output operation
or read operation, and then input a start instruction. Figure 25 shows this procedure.
First, input the condition. Then transmit 9 clocks (dummy clocks) of SCL. During this time, the
microprocessor sets the SDA line to high level.
acknowledge output operation or data output, so input the start condition
input, the E
operation is then possible.
*1. After 9 clocks (dummy clocks), if the SCL clock continues to be output without a start condition
Remark It is recommended to perform the above reset using dummy clocks when the system is
_00
being input, a write operation may be started upon receipt of a stop condition. To prevent this, input
a start condition after 9 clocks (dummy clocks).
SDA
SCL
2
PROM can be reset by the start and stop instructions. When the E
initialized after the power supply voltage has been raised.
2
PROM is reset. To make doubly sure, input the stop condition to the E
2
PROM]
condition
Start
2
PROM (after matching the phase with the microprocessor) and input an instruction.
2
PROM is accessed
1
Figure 25 Resetting E
Seiko Instruments Inc.
Dummy clock
2
8
2
PROM. In other words, the E
By this operation, the E
9
2
PROM
2-WIRE CMOS SERIAL E
condition
Start
2
2
*1
PROM, it must be reset by
PROM is reading data “0” or
. When a start condition is
2
PROM interrupts the
2
2
PROM retains the
PROM cannot be
2
PROM. Normal
condition
S-24CS64A
Stop
2
PROM is not
2
PROM
21